ArticleJournal of the Society for Cardiovascular Angiography & Interventions2025
Deformation of Surgically Implanted Aortic Valves: CT Findings Prior to Valve-in-Valve Implantation and Association With Mechanism of Failure.
Article in Journal of the Society for Cardiovascular Angiography & Interventions, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- New Horizons in Transcatheter Aortic Valve Replacement: Expectations and Preparations.Journal of clinical medicine · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Degeneration of surgically implanted bioprosthetic valves (BPVs) has been linked to risk factors including BPV construct and patient comorbidities. However, the role of the intrinsic structural configuration and potential structural changes of the surgical BPV itself on valve failure is unclear. Methods: Patients who underwent cardiac computed tomography prior to aortic valve-in-valve due to surgical BPV failure were enrolled. Assessment included BPV ring dimensions, strut angles, strut-to-strut distance, and projected geometric orifice area (PGOA), defined as the area of the circle connecting the distal aspects of the struts. These measurements were compared with those of nonimplanted surgical BPVs matched for valve type and size. Echocardiograms were obtained before the valve-in-valve procedure, and valve structure and function were assessed. Mechanism of BPV failure was classified as aortic stenosis, aortic regurgitation, or mixed. Results: A total of 222 patients were included. Aortic stenosis occurred in 111 (50%), aortic regurgitation in 55 (24.8%), and mixed in 56 (25.2%). Moderate/severe ring deformation (eccentricity index >10%) was present in 17% of cases. Strut angles, strut-to-strut distance, and PGOA were all significantly smaller in implanted than in reference valves (all Conclusions: Potential intrinsic changes (frame deformation) affect stented surgical BPVs implanted in aortic position. Whether these changes are associated with early valve degeneration and failure remains unknown.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.