ArticleBMC ophthalmology2025
Intraocular pressure correlation to progressive retinal nerve fiber layer loss in primary open angle glaucoma as measured by standard and modified goldmann applanation tonometers.
Article in BMC ophthalmology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Sectoral Analysis of Corneal Thickness in Glaucoma and Healthy Eyes and Its Relationship with RNFL and Rim Area.Journal of clinical medicine · 2026Article
- Intraocular Pressure Accuracy Post-Myopic Laser in situ Keratomileusis: Pivotal Study Results, Standard vs Correcting Applanation Tonometry Surface Goldmann Tonometry.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Deep Learning-Predicted RNFL Loss and Incident Glaucoma in the Canadian Longitudinal Study on Aging.Ophthalmology. GlaucomaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeCharacterize the relationship between intraocular pressure (IOP) as measured by standard and modified Goldmann prisms and the progressive loss of retinal nerve fiber layer (RNFL) in a cohort of glaucoma patients.
designRetrospective cross-sectional cohort data analysis.
participantsThe study included all patients from a database of 1927 eyes, 966 patients with same visit sequential standard and modified Goldmann IOP measurements. From the database, 148 eyes, 75 patients met the inclusion criteria of a diagnosis of primary open angle glaucoma (POAG) with at least 5 sequential quality optical coherence tomographer (OCT) measurements.
methodsSequential OCT images were obtained with the spectral domain Zeiss OCT5000. Participants were all diagnosed with POAG by untreated IOP ≥ 22, disk changes, and visual field (HVF) loss consistent with glaucomatous optic neuropathy (GON). Included were 575 Goldmann IOP measurements with standard and modified prisms affixed to the Goldmann applanation tonometer (GAT) armature. A modified prism includes a corneal conforming applanation surface minimizing the cornea's contribution to the IOP measurement. The study included a total of 940 OCT visits with an average of 6.3 visits per eye over an average of 4.9 years. Retinal nerve fiber layer (RNFL) loss rate was calculated by serial linear fit of average RNFL thickness measurements. Demographics as well as central corneal thickness (CCT) and corneal hysteresis (CH) data were also collected. OUTCOME MEASURES: Pearson correlation coefficients and random coefficient models were used to evaluate the relationship between mean standard and modified IOP measurements and RNFL thickness measurements over time in POAG subjects. Secondary outcomes of CCT and CH correlation to RNFL were similarly analyzed.
resultsFor all 148 POAG eyes, the overall rate of RNFL loss for an average standard GAT IOP of 17.9 mmHg was 1.08 µm per year (p = 0.002). Each 1-mmHg increase in standard GAT IOP was associated with an additional RNFL loss of 0.047 µm per year (r = 0.153, p = 0.06). Each 1-mmHg increase in modified GAT IOP was associated with an additional RNFL loss of 0.084 µm per year (r = 0.289, p = 0.0005). A modified prism IOP measurement ≥ 22 mmHg indicates a 2.57 times greater probability of significant RNFL loss than a standard prism IOP measurement ≥ 22 mmHg, p < 0.0001.
conclusionsHigher levels of GAT IOP during follow-up were related to higher rates of progressive RNFL loss detected by optic nerve OCT in treated POAG. A modified GAT prism surface demonstrates a significantly increased sensitivity, reliability and differentiation to progressive RNFL loss when compared to a standard GAT prism measured IOP. PRéCIS: A modified applanation surface prism with a corneal conforming shape used on a Goldmann tonometer appears to be a more sensitive and reliable indicator of progressive glaucomatous optic neuropathy as measured by retinal nerve fiber layer changes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.