Evidence map›Paper›PMID 40307746›Full record

ArticleBMC musculoskeletal disorders2025

What is the appropriate axial position in cannulated screw fixation for femoral neck fractures? A finite element analysis.

Dae-Kyung Kwak, Yeji Lee, Sung-Jae Lee, Seunghun Lee, Je-Hyun Yoo

Erratum issuedAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Dae-Kyung Kwak *Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University School of Medicine, Anyang, South Korea.
Yeji Lee *Department of Biomedical Engineering, Inje University, Gimhae, South Korea.
Sung-Jae LeeDepartment of Biomedical Engineering, Inje University, Gimhae, South Korea.
Seunghun LeeDepartment of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University School of Medicine, Anyang, South Korea.
Je-Hyun YooDepartment of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University School of Medicine, Anyang, South Korea. oships@hallym.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCannulated screw fixation is a common surgical treatment for femoral neck fractures; however, there is limited information on the optimal axial position of the screws. Herein, we aimed to investigate the impact of axial screw position on surgical stability in femoral neck fracture models fixed with three cannulated screws.

methodsEighteen finite element models (FEMs) replicating Pauwels type II femoral neck fractures were constructed and tested using nine normal and nine osteoporotic bone models. Each FEM simulated combinations of three different screw positions (anterior, central, and posterior) in the axial view and three models (type 1: 8° angles, 10 mm inter-screw interval; type 2: 6° angles, 10 mm inter-screw interval; type 3: 8° angles, 6 mm inter-screw interval), assuming anatomical reduction. Stress concentrations on the screws and bone were investigated, with measurements of peak von Mises stress (PVMS) and mean stress.

resultsStress concentration on the cannulated screws was consistently observed at the inferior screw near the fracture site in all FEMs. Stress concentrations on the bone around the screws were noted around the head and tip of the inferior screw in each FEM. All PVMS on the screw and surrounding bone decreased as the screw position moved from posterior to anterior in the axial view. Additionally, these stresses decreased as the screw tilt angle increased and the inter-screw interval was maximized. The mean stresses over the region of interest in all FEMs showed similar patterns to those of the PVMSs.

conclusionTo enhance fixation stability and reduce stress concentrations at the fracture site and lateral cortex in femoral neck fractures fixed with three canulated screws, positioning the screws anterior to the center in the axial view and maximizing the inter-screw interval, tailored to the patient's femur geometry, are recommended.

Indexed as

Bone ScrewsFemoral Neck FracturesFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaHumansStress, MechanicalAxial positionCannulated screwsFemoral neck fractures

Identifiers

PMID40307746
PMCPMC12042349

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.