Evidence map›Paper›PMID 40307271›Full record

ArticleScientific reports2025

Data selection strategies for minimizing measurement time in materials characterization.

Alexander Liehr, Kristina Dingel, Daniel Kottke, Sebastian Degener, David Meier, Bernhard Sick, Thomas Niendorf

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alexander LiehrInstitute of Materials Engineering, University of Kassel, Moenchebergstr. 3, 34125, Kassel, Germany. liehr@uni-kassel.de.ORCID https://orcid.org/0000-0001-7704-7809
Kristina DingelIntelligent Embedded Systems, University of Kassel, Wilhelmshöher Allee 71-73, 34121, Kassel, Germany.ORCID http://orcid.org/0000-0002-2348-8470
Daniel KottkeIntelligent Embedded Systems, University of Kassel, Wilhelmshöher Allee 71-73, 34121, Kassel, Germany.
Sebastian DegenerBundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, 12205, Berlin, Germany.ORCID https://orcid.org/0000-0002-8377-9026
David MeierIntelligent Embedded Systems, University of Kassel, Wilhelmshöher Allee 71-73, 34121, Kassel, Germany.
Bernhard SickIntelligent Embedded Systems, University of Kassel, Wilhelmshöher Allee 71-73, 34121, Kassel, Germany.
Thomas NiendorfInstitute of Materials Engineering, University of Kassel, Moenchebergstr. 3, 34125, Kassel, Germany.ORCID http://orcid.org/0000-0003-2622-5817

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Every new material needs to be assessed and qualified for an envisaged application. A steadily increasing number of new alloys, designed to address challenges in terms of reliability and sustainability, poses significant demands on well-known analysis methods in terms of their efficiency, e.g., in X-ray diffraction analysis. Particularly in laboratory measurements, where the intensities in diffraction experiments tend to be low, a possibility to adapt the exposure time to the prevailing boundary conditions, i.e., the investigated microstructure, is seen to be a very effective approach. The counting time is decisive for, e.g., complex texture, phase, and residual stress measurements. Traditionally, more measurement points and, thus, longer data collection times lead to more accurate information. Here, too short counting times result in poor signal-to-background ratios and dominant signal noise, respectively, rendering subsequent evaluation more difficult or even impossible. Then, it is necessary to repeat experiments with adjusted, usually significantly longer counting time. To prevent redundant measurements, it is state-of-the-art to always consider the entire measurement range, regardless of whether the investigated points are relevant and contribute to the subsequent materials characterization, respectively. Obviously, this kind of approach is extremely time-consuming and, eventually, not efficient. The present study highlights that specific selection strategies, taking into account the prevailing microstructure of the alloy in focus, can decrease counting times in X-ray energy dispersive diffraction experiments without any detrimental effect on data quality for the subsequent analysis. All relevant data, including the code, are carefully assessed and will be the basis for a widely adapted strategy enabling efficient measurements not only in lab environments but also in large-scale facilities.

Identifiers

PMID40307271
PMCPMC12043836

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.