Evidence map›Paper›PMID 40301908›Full record

ArticleRadiation oncology (London, England)2025

Application of 3D-printed compensators for proton pencil beam scanning of shallowly localized pediatric tumors.

Agnieszka Wochnik, Tomasz Kajdrowicz, Gabriela Foltyńska, Dawid Krzempek, Katarzyna Krzempek, Krzysztof Małecki, Marzena Rydygier, Jan Swakoń, Paweł Olko, Renata Kopeć

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Agnieszka WochnikInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland. Agnieszka.Wochnik@ifj.edu.pl.
Tomasz KajdrowiczInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Gabriela FoltyńskaInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Dawid KrzempekInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Katarzyna KrzempekInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Krzysztof MałeckiUniversity Children's Hospital of Krakow, Krakow, Poland.
Marzena RydygierInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Jan SwakońInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Paweł OlkoInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
Renata KopećInstitute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.

Funding

EU Project POWR.03.02.00-00-I004/16Horizon 2020 project INSPIRE Grant Agreement 730983
6 · The paper itself

Abstract

backgroundIn modern proton radiotherapy facilities with pencil beam scanning technology, the lowest energy of a proton beam typically ranges between 60 and 100 MeV, corresponding to a proton range in water of 3.1-7.5 cm. The irradiation of superficial lesions usually requires the application of a range shifter (RS) to further reduce the proton range. A certain distance from the patient to the RS increases the spot size, causing worse plan conformity. As an alternative solution, a patient-specific 3D-printed proton beam compensator (BC) can be applied to reduce the air gap and beam scattering. MATERIALS AND

methodsThis study is based on treatment planning system simulations using retrospectively selected data from six pediatric patients with diagnosed sarcomas located in the head and neck area. For three of these patients, 3D-printed compensators were utilized during the treatment phase, prior to the retrospective analysis. Treatment plans for children with shallow lesions treated using RSs and BCs were compared. Planning target volume constraints (D

resultsThe application of BCs reduced the low-dose irradiation areas, improved conformity and reduced critical organs exposure. BCs decreased the lateral spot size by approximately 57% and the penumbras by 41-47% at different depths in the cube target. The variation in BC homogeneity was less than 3.5%, meeting the criteria for plan robustness evaluation.

conclusionsCompared with RS placement at the nozzle, the placement of 3D-printed BCs in the near vicinity of the patient for the treatment of superficial tumors led to a more conformal dose distribution.

Indexed as

Head and Neck NeoplasmsPrinting, Three-DimensionalProton TherapyRadiotherapy Planning, Computer-AssistedSarcomaAdolescentChildChild, PreschoolFemaleHumansMaleOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetrospective Studies3D-printed beam compensatorsAdditive technologyPediatric tumorsPencil beam scanningProton radiotherapyRange discriminators

Identifiers

PMID40301908
PMCPMC12042327

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.