Evidence map›Paper›PMID 40301872›Full record

ArticleEuropean journal of medical research2025

LPM electrode loaded with RAPA-PLGA drug sustained-release system can reduce local fibrous tissue hyperplasia and local bioelectrical impedance.

Xiu Wang, Wentao Du, Yunyun Wang, Ahsan Riaz Khan, Haijun Zhang

Abstract read
In one paragraph

Article in European journal of medical research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiu WangCollege of Clinical Medicine, Hebei University of Engineering, Handan, 056000, China.
Wentao DuDepartment of Cardiovascular Medicine, Affiliated Hospital of Hebei Engineering University, Handan, 056000, Hebei, China. 1961147104@qq.com.
Yunyun WangCollege of Clinical Medicine, Hebei University of Engineering, Handan, 056000, China.
Ahsan Riaz KhanDepartment of Interventional and Vascular Surgery, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, 200072, China.
Haijun ZhangCollege of Clinical Medicine, Hebei University of Engineering, Handan, 056000, China. zhanghaijun@tongji.edu.cn.

Funding

National Key Research and Development Program of China 2023YFC2411900
6 · The paper itself

Abstract

objectiveThis study aims to design and fabricate a leadless pacemaker (LPM) electrode loaded with rapamycin (RAPA)-poly(lactic-co-glycolic acid) (PLGA) drug sustained-release system to reduce the local fibrous tissue proliferation after LPM implantation, reduce local bioelectrical impedance, and facilitate the safe extraction of LPM after use.

methodsWe fabricated an LPM electrode loaded with the RAPA-PLGA drug-sustained-release system and carried out in vitro and in vivo experiments to verify its effect.

resultsA scanning electron microscope showed that the LPM electrode cavity was loaded with the RAPA-PLGA drug's sustained-release system. The energy-dispersive spectrometer showed that the LPM electrode had RAPA and PLGA-related elements. The average drug loading rate of the drug sustained-release system was (51.02% ± 2.66) %, and the encapsulation rate was (85.04% ± 4.43%). The RAPA loaded in the electrode chamber was about (337.83 ± 53.66)μg. In vitro release results show that the LPM electrode loaded with RAPA-PLGA can continue to release for 44 days. In vitro cell inhibition experiments showed that the drug-loaded electrode group had an obvious inhibitory effect on fibroblasts, and the difference between the groups was significant (p < 0.05). In vivo experiments showed that the local bioelectrical impedance of the drug-loaded electrode group is lower than that of the control group, with a difference between groups with statistical significance (p < 0.05). The histopathological analysis of tissue sections from the site of (LPM electrode implantation revealed reduced fibrous tissue hyperplasia in the drug-loaded electrode group compared to the control group. Additionally, H&E staining indicated that the implantation of drug-loaded electrodes did not induce abnormal alterations in the liver, heart, spleen, lung, or kidney tissues.

conclusionThe LPM electrode loaded with RAPA-PLGA demonstrates significant, sustained drug release and anti-proliferative effects in vitro. This drug-loaded electrode has been deemed safe for implantation in animal models. It can effectively inhibit local fibrous tissue proliferation and reduce local bioelectrical impedance, offering a technical strategy to prolong the in vivo functionality of LPMs and enhance clinical procedures.

Indexed as

HyperplasiaPacemaker, ArtificialPolylactic Acid-Polyglycolic Acid CopolymerSirolimusAnimalsDelayed-Action PreparationsElectric ImpedanceElectrodesElectrodes, ImplantedRabbitsDelayed-Action PreparationsPolylactic Acid-Polyglycolic Acid CopolymerSirolimusElectrodeFibrous tissue hyperplasiaLeadless pacemakersPLGARapamycin

Identifiers

PMID40301872
PMCPMC12042559

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked