Evidence map›Paper›PMID 40301209›Full record

ArticleJournal of the Association for Research in Otolaryngology : JARO2025

Acoustical Effects of Tympanostomy Tube Attachment to Human Tympanic Membrane.

Arash Ebrahimian, Hossein Mohammadi, Hamid Motallebzadeh, Nima Maftoon

Abstract read
In one paragraph

Article in Journal of the Association for Research in Otolaryngology : JARO, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Arash EbrahimianDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada.ORCID http://orcid.org/0000-0003-4571-9177
Hossein MohammadiDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada.ORCID http://orcid.org/0000-0002-9073-1004
Hamid MotallebzadehDepartment of BioMedical Engineering, McGill University, Montréal, QC, Canada.ORCID http://orcid.org/0000-0003-3390-5263
Nima MaftoonDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada. nmaftoon@uwaterloo.ca.ORCID http://orcid.org/0000-0003-0853-996X

Funding

Objective and noninvasive diagnosis of middle-ear and conductive pathologies using simulation-based inference and transfer learning applied to clinical dataR21DC020274 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI MOTALLEBZADEH, HAMID · 2022 to 2024
$549k
Canada Foundation for Innovation 38964CIHR PJT-189955Natural Sciences and Engineering Research Council of Canada RGPIN-2020-05522New Frontiers in Research Fund (CA) NFRFE-2022-00351NIDCD NIH HHS R21 DC020274NIDCD NIH HHS R21DC020274
6 · The paper itself

Abstract

purposeSeveral therapeutic approaches for hearing disorders involve attaching medical devices to the tympanic membrane. The attachment of these devices can change the mechanical and acoustical properties of the middle ear, affecting the middle-ear vibrations. The alteration of passive mechanical properties results from the mass, stiffness, and geometry of the attached device. Additionally, procedures like tympanostomy tube attachment create perforations on the tympanic membrane, altering both the mechanical and acoustical properties of the middle ear. This study examined the acoustical effects of these as well as the combination of acoustical and mechanical effects of the attached devices on middle-ear vibrations.

methodsA finite-element model of the middle ear, including the middle-ear cavity, was used to systematically study the effects of perforation size and location on vibration outputs. Experimental data from the literature were used to tune the model. This model was then employed to investigate the combined mechanical and acoustical effects of tympanostomy tubes on vibration outputs.

resultsIn presence of both the mechanical effects of the device (due to its mass and stiffness) and the acoustical effects of it (due to perforations), the reduction in the motion of the stapes footplate resulting from the acoustical effects is more remarkable at low frequencies (below about 1 kHz). However, at higher frequencies, the mechanical effects of the device are dominant.

conclusionThe findings of this study provide insights into the optimal design of the shape, location, and other characteristics of medical devices implanted on the tympanic membrane.

Indexed as

AcousticsMiddle Ear VentilationTympanic MembraneFinite Element AnalysisHumansModels, BiologicalVibrationFinite-element modelHearing implantsMedical-device attachmentMiddle-ear acousticsMiddle-ear cavityMiddle-ear implantsMiddle-ear mechanicsPerforationsTympanostomy tubeVentilation tube

Identifiers

PMID40301209
PMCPMC12134247

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.