ArticleEuropean radiology2025

Correlation between perfusion and dual-layer spectral-detector CT in patients with cerebrovascular disorders.

Qin Liu, Xiaodan Lu, Qihuan Lin, Na Zhu, Yikai Xu

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Qin Liu *Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China.
Xiaodan Lu *Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China.
Qihuan LinDepartment of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China.
Na ZhuDepartment of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China.
Yikai XuDepartment of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, People's Republic of China. yikaixu917@gmail.com.ORCID http://orcid.org/0000-0002-4871-3785

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the correlation of cerebral perfusion parameters and iodine density (ID) map between conventional CT perfusion (CTP) and dual-layer spectral-detector CT (DLCT) in patients with cerebrovascular diseases. MATERIALS AND

methodsThis study enrolled 163 patients with cerebrovascular disorders who received CTP and CT angiography examination by DLCT. Conventional CTP (cCTP), spectral virtual monochromatic images (VMIs) CTP (sCTP, from 40 keV to 70 keV in 10 keV increments, and 100 keV), and ID maps were reconstructed. CTP parameters included cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to peak (TTP) were generated from cCTP and sCTP. The differences and consistency between the cCTP and sCTP parameters were compared by the Kruskal-Wallis Test and Bland-Altman plots. The correlations between the ID maps and the cCTP or sCTP parameters were analyzed by the Spearman test.

resultsSignificant differences were observed in both sides of CBV, MTT, TTP, and left-sided CBF between cCTP and sCTP (p < 0.05). Bland-Altman plots demonstrated that the absolute values of CBF, CBV, MTT from 60 keV VMIs and nearly all relative sCTP values had good consistency with cCTP (p ≥ 0.05). Correlation analysis revealed that relative ID exhibited good correlation with relative CBF from cCTP (r = 0.673, p < 0.001), 50 keV (r = 0.604, p < 0.001), 60 keV (r = 0.628, p < 0.001), and 70 keV (r = 0.614, p < 0.001) VMIs.

conclusionsCerebral perfusion parameters from sCTP show good consistency with those from cCTP. Additionally, the relative ID maps demonstrate good correlations with the relative CBF. KEY POINTS: Question Conventional brain CT perfusion is limited by high radiation dose, while quantitative dual-layer spectral-detector CT has been investigated as a low-dose alternative to perfusion measurement. Findings Dual-layer spectral detector CT-derived perfusion parameters showed good consistency with conventional brain CT perfusion, with the highest correlation with relative iodine density. Clinical relevance This study shows that dual-layer detector spectral CT-derived perfusion parameters, especially iodine density, have potential value to evaluate cerebral hemodynamics with less radiation dose and rapid imaging speed compared with conventional cerebral CTP.

Indexed as

Cerebral AngiographyCerebrovascular DisordersComputed Tomography AngiographyTomography, X-Ray ComputedAdultAgedAged, 80 and overCerebrovascular CirculationContrast MediaFemaleHumansMaleMiddle AgedRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesContrast MediaCerebrovascular disordersComputed tomographyDual-energyIodinePerfusion imaging