ArticleAnnals of nuclear medicine2025
Test for shortening the computation time for imaging of appearance time for cerebral blood using H
Article in Annals of nuclear medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
objectiveDelayed appearance of blood in the brain may be a pathophysiological indicator of stenosis or occlusion. Image computation for blood appearance generally requires considerable time. Therefore, in this study, we aimed to shorten the computation time using several algorithms and tested their accuracy and precision using examination data and simulations, as well as the computation time.
methodsWe retrospectively analyzed the images of patients with suspected cerebrovascular disorders who underwent PET study with
resultsThe computation time was 28.2 ± 6.2 min, 16.6 ± 3.9 min, and 2.6 ± 1.1 min for modes without fixing, with fixing blood volume, and washout rate, respectively. The mean difference in the appearance time against ROI-based non-linear fitting was less than 1 s with a standard deviation (SD) of approximately 2.5 s for those modes. The images obtained were similar for all three modes. The simulation showed that SD on the estimated appearance times were acceptable, namely < 1.5 s, for these modes.
conclusionThis study suggests the possibility of visualizing appearance time images in the brain with a reasonable computation time of approximately 2.5 min at the minimum and 30 min at the most.
Indexed as
Identifiers
40299309What OpenQuestion holds
Registered trials