Clarity of surgical field displayed on 3D monitor with local dimming technology during heads-up surgery.

Kosuke Nakajima, Jun Takeuchi, Tadashi Yokoi, Masaharu Mizuno, Takashi Koto, Tomoka Ishida, Hitomi Ozawa, Makoto Inoue

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Japanese journal of ophthalmology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kosuke NakajimaKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Jun TakeuchiKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Tadashi YokoiKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Masaharu MizunoKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Takashi KotoKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Tomoka IshidaKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan.
Hitomi OzawaDepartment of Clinical Engineering, Kyorin University Hospital, Tokyo, Japan.
Makoto InoueKyorin Eye Center, Department of Ophthalmology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan. inoue-eye@ks.kyorin-u.ac.jp.ORCID http://orcid.org/0000-0001-9887-3210

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the clarity of images displayed on a 3D local dimming technology (LDT) monitor (LMD-XH550MT) to that on a conventional 3D monitor (LMD-X550MT) integrated into the Artevo 800 STUDY

designLaboratory investigation

methodsSix vitreoretinal surgeons evaluated the clarity of the surgical field on photographs displayed simultaneously on 2 monitors during cataract and vitreous surgery by the Artevo 800

resultsThe mean visibility scores were significantly higher with the LDT monitor at 4.7±0.1 than with the conventional monitor at 2.9±0.1 (P<0.001). The visibility scores for anterior capsulotomy (P=0.034), phacoemulsification (P=0.036), cortex aspiration (P=0.036), core vitrectomy (P=0.035), peeling of epiretinal membrane (P=0.036), and ILM (P=0.036) were significantly higher with the LDT monitor than with the conventional monitor. The absolute value of skewness during anterior segment surgery was significantly lower with the LDT monitor (0.20±0.05) than with the conventional monitor (-0.44±0.06, P=0.03).

conclusionHigher contrast with the LDT monitor was attained by adjusting the backlight brightness according to the brightness of the images, which provided better image clarity for 3D heads-up cataract and vitreous surgery.