Evidence map›Paper›PMID 40297232›Full record

ArticleArXiv2025

A quantum computing approach to beam angle optimization.

Nimita Shinde, Ya-Nan Zhu, Haozheng Shen, Hao Gao

Abstract readPreprint
In one paragraph

Article in ArXiv, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nimita ShindeDepartment of Radiation Oncology, University of Kansas Medical Center, USA.
Ya-Nan ZhuDepartment of Radiation Oncology, University of Kansas Medical Center, USA.
Haozheng ShenUniversity of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai, China.
Hao GaoDepartment of Radiation Oncology, University of Kansas Medical Center, USA.

Funding

Novel Optimization Methods and Treatment Planning System for Clinically-Deliverable Truly-Hybrid Proton-Photon RadiotherapyR37CA250921 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI Hao Gao · 2021 to 2026
$2.2M
Simultaneous dose and dose rate optimization for clinical FLASH proton radiotherapyR01CA261964 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI GAO, HAO · 2022 to 2025
$2.0M
NCI NIH HHS R01 CA261964NCI NIH HHS R37 CA250921
6 · The paper itself

Abstract

Background: Beam angle optimization (BAO) is a critical component of radiation therapy (RT) treatment planning, where small changes in beam configuration can significantly impact treatment quality, especially for proton RT. Mathematically, BAO is a mixed integer programming (MIP) problem, which is NP-hard due to its exponential growing search space. Traditional optimization techniques often struggle with computational efficiency, necessitating the development of novel approaches. Purpose: This study introduces QC-BAO, a hybrid quantum-classical approach that leverages quantum computing to solve the MIP formulation of BAO. Methods: The proposed approach, QC-BAO, models BAO as an MIP problem, incorporating binary variables for beam angle selection and continuous variables for optimizing spot intensities for proton therapy. The proposed approach employs a hybrid quantum-classical framework, utilizing quantum computing to solve the binary decision component while integrating classical optimization techniques, including iterative convex relaxation and the alternating direction method of multipliers. Results: Computational experiments were conducted on clinical test cases to evaluate QC-BAO's performance against clinically verified angles and a heuristic approaches, GS-BAO and AG-BAO. QC-BAO demonstrated improved treatment plan quality over clinical, GS-BAO and AG-BAO-selected angles. QC-BAO consistently increased the conformity index (CI) for target coverage while reducing mean and maximum doses to organs-at-risk (OAR). For instance, in the lung case, QC-BAO achieved a CI of 0.89, compared to 0.89 (clinical), 0.76 (GS-BAO) and 0.86 (AG-BAO), while lowering the mean lung dose to 2.78 Gy from 3.36 Gy (clinical), 4.80 Gy (GS-BAO) and 3.03 Gy (AG-BAO). Additionally, QC-BAO produced the lowest objective function values, confirming its superior optimization capability. Conclusions: The findings highlight the potential of quantum-inspired algorithm to enhance the solution to BAO problem by demonstrated improvement in plan quality using the proposed method, QC-BAO. This study paves the way for future clinical implementation of quantum-accelerated optimization in RT.

Indexed as

beam angle optimizationmixed integer programmingquantum optimization

Identifiers

PMID40297232
PMCPMC12036446

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.