ArticleSensors (Basel, Switzerland)2025
A
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A Bioinspired Flexible Pressure Sensor with High Linearity Based on a Three-Dimensional Porous Structure.Biomimetics (Basel, Switzerland) · 2026Article
- Comb-Tipped Coupled Cantilever Sensor for Enhanced Real-Time Detection ofSensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Passive-wireless surface-acoustic-wave (SAW) micro-pressure sensors are suitable for extreme scenarios where wired sensors are not applicable. However, as the measured pressure decreases, conventional SAW micro-pressure sensors struggle to meet expected performance due to insufficient sensitivity. This article proposes a a method of using an A2-mode Lamb SAW sensor and introduces an inertial structure in the form of a cantilever beam to enhance sensitivity. An MEMS-compatible manufacturing process was employed to create a multi-layer structure of SiO2, AlN, and SOI for the SAW micro-pressure sensor. To investigate the operational performance of the SAW micro-pressure sensor, a micro-pressure testing system was established. The experimental results demonstrate that the sensor exhibits high sensitivity to micro-pressure, validating the effectiveness of the proposed design.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.