Evidence map›Paper›PMID 40291625›Full record

ArticleOrthopaedic journal of sports medicine2025

Biomechanical Comparison of a Novel PEEK Tibial Cortical Suspension Device With 6 Metallic Femoral Cortical Suspension Devices Used in Anterior Cruciate Ligament Reconstruction.

Apurve Parameswaran, Suraj Kumar Choudhary Konka, Murtuza Ahmed Mohammed, Krishna Kiran Eachempati, Sunil Apsingi

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Apurve ParameswaranDepartment of Orthopaedics, Medicover Hospitals, HITEC City, Hyderabad, Telangana, India.ORCID https://orcid.org/0000-0003-2070-2256
Suraj Kumar Choudhary KonkaDepartment of Orthopaedics, Medicover Hospitals, HITEC City, Hyderabad, Telangana, India.ORCID https://orcid.org/0009-0003-1749-2443
Murtuza Ahmed MohammedDepartment of Orthopaedics, Medicover Hospitals, HITEC City, Hyderabad, Telangana, India.
Krishna Kiran EachempatiDepartment of Orthopaedics, Medicover Hospitals, HITEC City, Hyderabad, Telangana, India.ORCID https://orcid.org/0000-0003-1416-9918
Sunil ApsingiDepartment of Orthopaedics, Medicover Hospitals, HITEC City, Hyderabad, Telangana, India.ORCID https://orcid.org/0000-0002-6306-9860

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Conventional cortical suspensory fixation devices (CSFDs) are made of metal. Most adjustable-loop CSFDs originally intended for femoral-side fixation are also used on the tibial side during "all-inside" anterior cruciate ligament (ACL) reconstruction. The T-Button-A is a novel adjustable-loop polyether ether ketone (PEEK) CSFD intended specifically for tibial-side fixation during ACL reconstruction using the "full-tunnel" technique. Purpose/Hypothesis: The purpose of this study was to compare the biomechanical characteristics of the T-Button-A with those of 6 commercially available fixed- or adjustable-loop CSFDs. It was hypothesized that the T-Button-A would be comparable with conventional metallic CSFDs intended for femoral-side fixation in terms of its biomechanical properties. Study Design: Controlled laboratory study. Methods: Ten implants each, of T-Button-A, Tightrope RT, Proloop Ultra, Procinch RT, Infinity, Infiloop, and Endobutton CL Ultra were biomechanically tested using an axial and torsion testing machine, and an incremental load-based testing protocol comprising 3500 cycles. Elongation and load to failure on cyclic and pull-to-failure loading, respectively, were recorded for each implant and compared across all devices. The consistency of implants in completing the 3500 test cycles, and demonstrating cyclic elongation <3 mm as well as load to failure >650 N, was compared across the tested devices. Results: The T-Button-A demonstrated a mean elongation of 2.09 ± 0.43 mm, which was less than that of Infinity ( Conclusion: The biomechanical performance of the T-Button-A is comparable with most fixed- and adjustable-loop metallic CSFDs and is beyond what is considered acceptable to support ACL reconstruction grafts during early postoperative rehabilitation. Clinical Relevance: The PEEK T-Button-A is a viable alternative to conventional metallic CSFDs, for tibial-side fixation during ACL reconstruction.

Indexed as

ACLbiomechanics of ligamentgeneral sports traumaknee, generalknee, ligaments

Identifiers

PMID40291625
PMCPMC12033818

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.