Evidence map›Paper›PMID 40290355›Full record

ReviewJournal of emergencies, trauma, and shock

Implementation and Adaptation of Pathway of Resuscitative Endovascular Balloon Occlusion of the Aorta after Traumatic Injury.

Ammar Al-Hassani, Bianca M Wahlen, Ayman El-Menyar, Ibrahim Al-Hassani, Naushad A Khan, Sagar Galwankar, Sandro Rizoli, Hassan Al-Thani

Abstract readReview
In one paragraph

Review in Journal of emergencies, trauma, and shock. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ammar Al-HassaniDepartment of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar.
Bianca M WahlenDepartment of Anesthesiology, Hamad Medical Corporation, Doha, Qatar.
Ayman El-MenyarDepartment of Surgery, Trauma and Vascular Surgery, Clinical Research, Hamad Medical Corporation, Doha, Qatar.
Ibrahim Al-HassaniPre-Graduate Student, Weill Cornell Medicine, Doha, Qatar.
Naushad A KhanDepartment of Surgery, Trauma and Vascular Surgery, Clinical Research, Hamad Medical Corporation, Doha, Qatar.
Sagar GalwankarDepartment of Emergency Medicine, Sarasota Memorial Hospital, Florida State University, Sarasota, Florida, USA.
Sandro RizoliDepartment of Surgery, Trauma Surgery, Hamad Medical Corporation, Doha, Qatar.
Hassan Al-ThaniDepartment of Surgery, Trauma and Vascular Surgery, Hamad Medical Corporation, Doha, Qatar.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an invented method to facilitate a minimally invasive occlusion of the aorta to stop a life-threatening hemorrhage. This review described an established pathway for noncompressible exsanguination (REBOA procedures) in trauma patients at a Level 1 trauma center. A detailed description starting from the structural changes of the hospital and facilities itself, the initial thoughts, implementation of the process, and continuous revision and improvement of guidelines were discussed. A multidisciplinary core team consisting of trauma surgeons, anesthesiologists, interventional radiologists, and operating room (OR) staff developed step-by-step clinical practice guidelines for using REBOA at our trauma center. A comprehensive training program for specialized procedural training was implemented to ensure the competency of all relevant medical personnel in managing trauma patients. The REBOA guidelines underwent plan-do-check-act quality cycle improvement until the latest guidelines were reached with each use of REBOA in a trauma patient, leading to further auditing of the guidelines to identify areas for improvement. The current review discusses the critical role of adopting innovative technologies and adapting protocols in trauma care, particularly for vulnerable patients with a high risk of morbidity and mortality. Continuous process improvement, procedural refinement, and evolving guidelines are essential prerequisites for optimizing patient outcomes. We described a valuable framework for other trauma programs to implement and adapt similar endovascular bleeding control approaches, thereby potentially enhancing patient care.

Indexed as

Aortic rupturehemorrhagic controlhemostasisimplementationresuscitationresuscitative endovascular balloon occlusion of the aortatrauma

Identifiers

PMID40290355
PMCPMC12020937

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.