Evidence map›Paper›PMID 40288963›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2025

[Study on the separation method of lung ventilation and lung perfusion signals in electrical impedance tomography based on rime algorithm optimized variational mode decomposition].

Guobin Gao, Kun Li, Junyao Li, Mingxu Zhu, Yu Wang, Xiaoheng Yan, Xuetao Shi

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Research on electrical impedance tomography for pediatric pneumonia based on an improved radial basis function neural network].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Guobin GaoFaculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, Liaoning 125105, P. R. China.
Kun LiFaculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, Liaoning 125105, P. R. China.
Junyao LiDepartment of Biomedical Engineering, Air Force Medical University, Xi'an 710032, P. R. China.
Mingxu ZhuDepartment of Biomedical Engineering, Air Force Medical University, Xi'an 710032, P. R. China.
Yu WangInstitute of Medical Research, Northwestern Polytechnical University, Xi'an 710072, P. R. China.
Xiaoheng YanFaculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, Liaoning 125105, P. R. China.
Xuetao ShiDepartment of Biomedical Engineering, Air Force Medical University, Xi'an 710032, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Real-time acquisition of pulmonary ventilation and perfusion information through thoracic electrical impedance tomography (EIT) holds significant clinical value. This study proposes a novel method based on the rime (RIME) algorithm-optimized variational mode decomposition (VMD) to separate lung ventilation and perfusion signals directly from raw voltage data prior to EIT image reconstruction, enabling independent imaging of both parameters. To validate this approach, EIT data were collected from 16 healthy volunteers under normal breathing and inspiratory breath-holding conditions. The RIME algorithm was employed to optimize VMD parameters by minimizing envelope entropy as the fitness function. The optimized VMD was then applied to separate raw data across all measurement channels in EIT, with spectral analysis identifying relevant components to reconstruct ventilation and perfusion signals. Results demonstrated that the structural similarity index (SSIM) between perfusion images derived from normal breathing and breath-holding states averaged approximately 84% across all 16 subjects, significantly outperforming traditional frequency-domain filtering methods in perfusion imaging accuracy. This method offers a promising technical advancement for real-time monitoring of pulmonary ventilation and perfusion, holding significant value for advancing the clinical application of EIT in the diagnosis and treatment of respiratory diseases.

Indexed as

AlgorithmsLungPulmonary VentilationTomographyAdultElectric ImpedanceHumansImage Processing, Computer-AssistedBlood perfusionElectrical impedance tomographyPulmonary ventilationRime algorithmVariational mode decomposition

Identifiers

PMID40288963
PMCPMC12035631

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.