Evidence map›Paper›PMID 40287484›Full record

ArticleScientific reports2025

Experimental and numerical study of tubular steel columns with/without demountable bolted shear connectors embedded in the concrete.

Sabry Fayed, Moataz Badawi, Mohamed Ghalla, Ehab A Mlybari, Yahia Iskander, Saad A Yehia

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sabry FayedDepartment of Civil Engineering, Faculty of Engineering, Kafrelsheikh University, Kafrelsheikh, Egypt. sabry_fayed@eng.kfs.edu.eg.
Moataz BadawiDepartment of Civil Engineering, College of Engineering and Architecture, Umm Al-Qura University, Makkah, Saudi Arabia.
Mohamed GhallaDepartment of Civil Engineering, Faculty of Engineering, Kafrelsheikh University, Kafrelsheikh, Egypt.
Ehab A MlybariDepartment of Civil Engineering, College of Engineering and Architecture, Umm Al-Qura University, Makkah, Saudi Arabia.
Yahia IskanderDepartment of Civil Engineering, College of Engineering and Architecture, Umm Al-Qura University, Makkah, Saudi Arabia.
Saad A YehiaCivil Engineering Department, Higher Institute of Engineering and Technology, Kafrelsheikh, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three push-out specimens were experimentally tested to investigate the behavior of tubular steel columns (TSC) with and without bolted shear connectors embedded in normal concrete (NC). Each specimen consisted of a tubular steel column (TSC) encased in a 250 × 250 × 200 mm concrete cube The embedment/the prominent height of TSC was 100 mm. Foam was used underneath the TSC to form free space. The study considered variables such as the presence of demountable shear studs and reinforcement. The failure modes, load-slip response, peak load/slip, and shear stiffness of the specimens were analyzed. Furthermore, a finite element model (FEM) was developed using ABAQUS software to simulate the behavior of the tested specimens and validated against the experimental results. The FEM was also employed to conduct further parametric investigations. The results indicate that demountable shear studs significantly improve shear capacity, with specimens exhibiting a 217% higher peak load than those without studs. Reinforcing the concrete block had a negligible effect on peak load but increased peak slip by 37.7% and shear stiffness by 18.7% compared to the unreinforced specimen. Furthermore, increasing the TSC thickness significantly enhances peak load, with a 154.31% increase observed as the thickness increases from one-third of the bolt diameter to the full bolt diameter. Additionally, using TSC thicknesses greater than half the bolt diameter helps prevent bearing failure. Increasing the concrete compressive strength from 25 to 50 MPa leads to a 24.6% increase in peak load, while slip capacity decreases by 19.77%. For applications requiring high ductility, excessively high-strength concrete should be avoided, as it reduces slip capacity. The results also demonstrate that the bolt diameter should not exceed twice the TSC web thickness to prevent bearing failure.

Indexed as

3D modelDemountable bolted shear connectorsNormal concretePush-out testShear bearing capacitySteel tubular columns

Identifiers

PMID40287484
PMCPMC12033251

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.