Evidence map›Paper›PMID 40285250›Full record

ArticleSensors (Basel, Switzerland)2025

Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement.

Arthur F Andrade, Giovanny M B Galdino, Ronimack T Souza, Newton S S M Fonseca, Antonio F Leite Neto, Edson G Costa, Eden L Carvalho Junior

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Arthur F AndradeFaculty of Engineering, Languages and Social Sciences at Seridó, Federal University of Rio Grande do Norte (UFRN), Currais Novos 59380000, RN, Brazil.ORCID 0000-0002-0954-8748
Giovanny M B GaldinoElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429900, PB, Brazil.ORCID 0009-0007-3923-6554
Ronimack T SouzaElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429900, PB, Brazil.ORCID 0000-0003-0153-463X
Newton S S M FonsecaElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429900, PB, Brazil.ORCID 0000-0002-0018-7210
Antonio F Leite NetoElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429900, PB, Brazil.ORCID 0000-0002-1001-687X
Edson G CostaElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429900, PB, Brazil.ORCID 0000-0003-2998-2039
Eden L Carvalho JuniorTransmissoras Brasileiras de Energia (TBE), São Paulo 04551000, SP, Brazil.

Funding

Agência Nacional de Energia Elétrica PD-04734-0007/2020Transmissoras Brasileiras de Energia PD-04734-0007/2020
6 · The paper itself

Abstract

Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates. This study presents an autonomous lightning strike counter system utilizing a split-core Rogowski coil for non-invasive current measurement on transmission towers. The system combines the Rogowski coil with an active integrator circuit to reconstruct the incident current waveform from the coil voltage signal. A microcontroller-based processing unit records strike occurrences and classifies them by amplitude using predefined thresholds. Laboratory tests were carried out to evaluate the performance of the Rogowski coil and integrator circuit, validating the system accuracy in detecting current pulses associated with lightning strikes. Underway field tests will assess the sensor's reliability during long-term autonomous operation on 345-kV transmission towers. The results demonstrate that the proposed system represents a practical and cost-effective solution for lightning monitoring in remote areas, contributing to enhanced data collection for engineering studies and improved reliability of electrical infrastructure.

Indexed as

automationdischarge counterlightninglightning current measurementoverhead power lines monitoringRogowski coil

Identifiers

PMID40285250
PMCPMC12031593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.