Evidence map›Paper›PMID 40285232›Full record

ArticleSensors (Basel, Switzerland)2025

Dimensional Accuracy Evaluation of Single-Layer Prints in Direct Ink Writing Based on Machine Vision.

Yongqiang Tu, Haoran Zhang, Hu Chen, Baohua Bao, Canmi Fang, Hao Wu, Xinkai Chen, Alaa Hassan, Hakim Boudaoud

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yongqiang TuCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.ORCID 0000-0002-8895-4188
Haoran ZhangCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Hu ChenCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Baohua BaoCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Canmi FangCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Hao WuCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Xinkai ChenCollege of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China.
Alaa HassanInnovation Process Research Institute, University of Lorraine, F-54000 Nancy, France.ORCID 0000-0003-2477-1726
Hakim BoudaoudInnovation Process Research Institute, University of Lorraine, F-54000 Nancy, France.

Funding

Fujian Province Young and Middle-aged Teacher Education Research Project (Science and Technology) Key Project JZ230027Fujian Provincial Natural Science Youth Funding 2024J08195Xiamen Science and Technology Bureau Nature Funding 3502Z202471046
6 · The paper itself

Abstract

The absence of standardized evaluation methodologies for single-layer dimensional accuracy significantly hinders the broader implementation of direct ink writing (DIW) technology. Addressing the critical need for precision non-contact assessment in DIW fabrication, this study develops a novel machine vision-based framework for dimensional accuracy evaluation. The methodology encompasses three key phases: (1) establishment of an optimized hardware configuration with integrated image processing algorithms; (2) comprehensive investigation of camera calibration protocols, advanced image preprocessing techniques, and high-precision contour extraction methods; and (3) development of an iterative closest point (ICP) algorithm-enhanced evaluation system. The experimental results demonstrate that our machine vision system achieves 0.04 mm × 0.04 mm spatial resolution with the ICP convergence threshold optimized to 0.001 mm. The proposed method shows an 80% improvement in measurement accuracy (0.001 mm) compared to conventional approaches. Process parameter optimization experiments validated the system's effectiveness, showing at least 76.3% enhancement in printed layer dimensional accuracy. This non-contact evaluation solution establishes a robust framework for quantitative quality control in DIW applications, providing critical insights for process optimization and standardization efforts in additive manufacturing.

Indexed as

dimensional accuracy evaluationdirect ink writingmachine visionsingle layer

Identifiers

PMID40285232
PMCPMC12031616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.