Evidence map›Paper›PMID 40285070›Full record

ArticleSensors (Basel, Switzerland)2025

Validity of Heart Rate Variability Measured with Apple Watch Series 6 Compared to Laboratory Measures.

Lauren Bonneval, David Wing, Sydney Sharp, Maira Tristao Parra, Ryan Moran, Andrea LaCroix, Job Godino

Abstract readEvaluation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lauren BonnevalSan Diego General Preventive Medicine Residency, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.
David WingExercise and Physical Activity Resource Center, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.ORCID 0000-0003-1883-9448
Sydney SharpExercise and Physical Activity Resource Center, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.
Maira Tristao ParraExercise and Physical Activity Resource Center, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.
Ryan MoranSan Diego General Preventive Medicine Residency, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.ORCID 0000-0002-2219-5502
Andrea LaCroixExercise and Physical Activity Resource Center, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.
Job GodinoExercise and Physical Activity Resource Center, Herbert Wertheim School of Public Health and Human Longevity Science, University of California San Diego, La Jolla, CA 92093, USA.ORCID 0000-0002-4852-6277

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We assessed the test validity of the Apple Watch series 6 measure of heart rate variability (HRV) by comparing it with the reference measure assessed via a Biopac 3-lead electrocardiogram (ECG). We recruited 78 healthy adults (aged 20-75 years). HRV was measured using an in-lab protocol while resting, talking, watching a movie, before walking, and after walking. We conducted a synchronized countdown for each condition to guarantee that the recordings would be aligned between the two devices by using event markers in the Biopac at the exact time that the Apple Watch Breathe app began and ended. We assessed test validity using the Bland-Altman method, and both precision and accuracy were estimated using Lin's concordance correlation coefficient. The highest level of agreement and concordance between devices occurred during rest. We observed near-perfect agreement for R-R intervals and beats per minute (BPM) measures, with mean absolute percentage errors (MAPE) of 1.15% during resting conditions. We observed moderate levels of agreement and concordance for N-N intervals at rest with a MAPE of 31.31% during resting conditions. The Apple Watch provides a high level of validity for measuring R-R intervals and BPM in healthy adults. Further research is needed to determine if HRV measures with the Apple Watch offer a significant opportunity for the surveillance of CVD risk.

Indexed as

HeartHeart RateWearable Electronic DevicesAdultAgedElectrocardiographyFemaleHeart Rate DeterminationHumansMaleMiddle AgedApple Watchcardiovascular disease (CVD)heart rate variability (HRV)

Identifiers

PMID40285070
PMCPMC12031371

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.