ArticleMicromachines2025
Design and Driving Characteristics of a Bidirectional Micro-Device Based on Multi-Electrothermal Co-Actuation.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In this paper, a bidirectional micro-device based on multi-electrothermal co-actuation is proposed for a fuze safety system, combining the advantages of the simple structure, small size, low input voltage, large output, and absence of electromagnetic interference in electrothermal actuators. Based on the working principle of the multi-electrothermal co-actuation device and the mathematical model of the single V-shaped electrothermal actuator established in this paper, the temperature distribution of the V-shaped electrothermal actuator is simulated. In addition, the dynamic response and the effect of geometric factors on the output performance of the multi-electrothermal co-actuation device are analyzed in detail. Furthermore, driving characteristics tests of the electrothermal micro-device are carried out. The experimental findings indicate that a displacement of approximately 258.95 μm with a response time of about 156.51 ms can be achieved by the V-shaped electrothermal actuator when the applied voltage is 1.2 V. In a single cycle, a total displacement of 340 μm is obtained by the co-actuation device in around 1.28 s.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.