Evidence map›Paper›PMID 40283337›Full record

ReviewMicromachines2025

Recent Advances in Microfluidics-Based Monitoring of Waterborne Pathogens: From Isolation to Detection.

Guohao Xu, Gaozhe Cai, Lijuan Liang, Jianxin Cheng, Lujie Song, Rui Sun, Feng Shen, Bo Liu, Shilun Feng, Jin Zhang

Abstract readReview
In one paragraph

Review in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Guohao XuCollege of Life and Geographic Sciences, Kashi University, Kashi 844000, China.
Gaozhe CaiSchool of Microelectronics, Shanghai University, Shanghai 201800, China.
Lijuan LiangState Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
Jianxin ChengJiaxing Key Laboratory of Biosemiconductors (A), Xiangfu Laboratory, Jiashan 314102, China.
Lujie SongDepartment of Urology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai 200233, China.
Rui SunJiaxing Key Laboratory of Biosemiconductors (A), Xiangfu Laboratory, Jiashan 314102, China.
Feng ShenJiaxing Key Laboratory of Biosemiconductors (A), Xiangfu Laboratory, Jiashan 314102, China.
Bo LiuJiaxing Key Laboratory of Biosemiconductors (A), Xiangfu Laboratory, Jiashan 314102, China.
Shilun FengState Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.ORCID 0000-0002-2560-2417
Jin ZhangCollege of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, China.

Funding

the equipment research and development projects of the ChineseAcademy of Sciences PTYQ2024YZ0010the Science and Technology Commission of Shanghai Municipality 22S31901700the Science and Technology Commission of Shanghai Municipality Project XTCX-KJ-2024-038This work was supported by grants from the National Key Research and Development Program of China No. 2023YFA0915200,2023YFA0915204
6 · The paper itself

Abstract

Waterborne pathogens seriously threaten human life and can cause diarrhea, gastrointestinal disorders, and more serious systemic infections. These pathogens are usually caused by contaminated water sources that contain disease-causing microorganisms, such as bacteria, viruses, and parasites, which cause infection and disease when they enter the human body through drinking water or other means. Due to the wide range of transmission routes and the high potential risk of waterborne pathogens, there is an urgent need for an ultrasensitive, rapid, and specific pathogenic microorganism monitoring platform to meet the critical monitoring needs of some water bodies' collection points daily monitoring needs. Microfluidics-based pathogen surveillance methods are an important stage towards automated detection through real-time and multi-targeted monitoring, thus enabling a comprehensive assessment of the risk of exposure to waterborne pathogens and even emerging microbial contaminants, and thus better protection of public health. Therefore, this paper reviews the latest research results on the isolation and detection of waterborne pathogens based on microfluidic methods. First, we introduce the traditional methods for isolation and detection of pathogens. Then, we compare some existing microfluidic pathogen isolation and detection methods and finally look forward to some future research directions and applications of microfluidic technology in waterborne pathogens monitoring.

Indexed as

detectionisolationlab-on-a-chip (LOC)microfluidic chipnucleic acid analysissample processingwaterborne pathogens

Identifiers

PMID40283337
PMCPMC12029729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.