ArticleMicromachines2025
Optical Fiber Methane Sensor Based on Mach-Zehnder Interferometer Induced by Multimode Interference.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
In this paper, based on the multimode interference structure fiber and the sensitive advantages of a zeolitic imidazolate framework-8/Polydimethylsiloxane (ZIF-8/PDMS)-sensitive film in methane detection, a methane sensor based on an interferometer induced by multimode interference is designed and built with the aid of modeling. The methane-sensitive single mode fiber (MS-SMF) is obtained by coating a ZIF-8/PDMS-sensitive film around the cladding of a thin-diameter SMF. The change in methane concentration leads to a change in the cladding mode of the MS-SMF, which causes a change in interference spectrum and realizes methane concentration sensing. The factors affecting the sensitivity of the methane sensor are analyzed. Methane sensors with various parameters are fabricated and tested on a methane sensor platform for performance estimation at methane concentrations of 0-4%. The experimental results show that the sensitivity of the sensor to methane reaches 2.364 nm/% when the length of the MS-SMF is 42 mm, the thickness of the sensitive film is 1.8 µm, and the diameter of the MS-SMF is 58 µm. The limit of detection is about 338 ppm. The average response time is 30 s and the recovery time is 45 s. The temperature sensitivity of the methane sensor is approximately 0.026 nm/°C. The experimental results verify the correctness of the methane sensor model. This study provides a new design idea for optical methane sensors, showing great application potential in the field of methane detection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.