Evidence map›Paper›PMID 40283267›Full record

ArticleMicromachines2025

Installation Error Calibration Method for Redundant MEMS-IMU MWD.

Yin Qing, Lu Wang, Yu Zheng

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yin QingSchool of Engineering and Technology, China University of Geosciences (Beijing), Beijing 100083, China.
Lu WangSchool of Engineering and Technology, China University of Geosciences (Beijing), Beijing 100083, China.ORCID 0000-0001-6702-5665
Yu ZhengSchool of Engineering and Technology, China University of Geosciences (Beijing), Beijing 100083, China.ORCID 0009-0002-4281-5163

Funding

Research and development of precision guided coring and drilling detection technology 2024ZD1003104
6 · The paper itself

Abstract

For Measurement While Drilling (MWD), the redundant Micro-Electro-Mechanical Systems Inertial Measurement Unit (MEMS-IMU) navigation system significantly enhances the reliability and accuracy of drill string attitude measurements. Such an enhancement enables precise control of the wellbore trajectory and enhances the overall quality of drilling operations. But installation errors of the redundant MEMS-IMUs still degrade the accuracy of drill string attitude measurements. It is essential to calibrate these errors to ensure measurement precision. Currently, the commonly used calibration method involves mounting the carrier on a horizontal plane and performing calibration through rotation. However, when the carrier rotates on the horizontal plane, the gravity acceleration component sensed by the horizontal axis of the IMU accelerometer in the carrier is very small, which leads to a low signal-to-noise ratio, so that the measured matrix obtained by the solution is dominated by noise. As a result, the accuracy of the installation is insufficient, and, finally, the effectiveness of the installation error compensation is reduced. In order to solve this problem, this study proposes a 45°-inclined six-position calibration method based on the selected hexagonal prism redundant structure for redundant MEMS-IMUs in MWD. Firstly, the compensation matrices and accelerometer measurement errors were analyzed, and the new calibration method was proposed; the carrier of the IMUs should be installed at an inclined position of 45°. Then, six measuring points were identified for the proposed calibration approach. Finally, simulation and laboratory experiments were conducted to verify the effectiveness of the proposed method. The simulation results showed that the proposed method reduced installation errors by 40.4% compared with conventional methods. The experiments' results demonstrated reductions of 83% and 68% in absolute measurement errors for the

Indexed as

error calibrationIMU-MEMSinstallation errorMWDredundancy technology

Identifiers

PMID40283267
PMCPMC12029845

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.