ArticleRadiologie (Heidelberg, Germany)2025
Improving image quality by comparing two chest MRI sequences: free-breathing T1-weighted Star-VIBE and breath-holding T1-weighted 3D VIBE Dixon.
Article in Radiologie (Heidelberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Achieving free-breathing liver magnetic resonance imaging by combining compressed sensing with the number of excitations.Abdominal radiology (New York) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo explore the feasibility of using magnetic resonance imaging (MRI) with T1-weighted free-breathing Star-VIBE sequences for improving image quality in chest examinations compared with conventional T1-weighted breath-hold VIBE (C-VIBE) sequences.
methodsThe data of 20 patients with chest MRI examinations in our hospital were prospectively collected. The scanning sequences included conventional breath-hold T1-weighted VIBE sequences (echo time [TE]: 1.29 ms; repetition time [TR]: 3.97 ms) and free-breathing T1-weighted Star-VIBE sequences (TE: 1.39 ms; TR: 2.79 ms). The signal intensity (SI) and standard deviation (SD) of the ascending aorta, pulmonary artery trunk, and descending aorta were measured at the level of the main pulmonary artery. The signal-to-noise ratio (SNR = SI/SD) and coefficient of variation (CV = SD/SI) of SI were calculated. The MR image quality was subjectively scored double-blindly using a 5-point scoring system by two radiologists who had more than 10 years' experience in diagnosing chest diseases and more than 5 years' experience in MR diagnosis of chest diseases.
resultsThe SNR of the ascending aorta, pulmonary artery trunk, and descending aorta with free-breathing T1-weighted Star-VIBE sequences was significantly higher than that of conventional breath-hold T1-weighted VIBE sequences (p < 0.05), while the CV of SI with the former sequences was significantly lower than that of the latter sequences (p < 0.05). The subjective scores of the two radiologists regarding the image quality of the two types of sequences had excellent consistency (κ > 0.80, p < 0.05); the subjective scores for free-breathing T1-weighted Star-VIBE sequences were significantly higher than for conventional breath-hold T1-weighted VIBE sequences (p < 0.05).
conclusionMagnetic resonance imaging with free-breathing T1-weighted Star-VIBE sequences can significantly improve image quality of chest studies compared with conventional breath-hold T1-weighted VIBE sequences.
Indexed as
Identifiers
40281328What OpenQuestion holds
Registered trials