Evidence map›Paper›PMID 40277572›Full record

ArticleBiosensors2025

Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating.

Nicholas Spurlock, Rosana Alfaro, William E Gabella, Kunal Chugh, Megan E Pask, Franz Baudenbacher, Frederick R Haselton

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nicholas SpurlockDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0009-0005-3411-5548
Rosana AlfaroDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.
William E GabellaDepartment of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0000-0003-2954-512X
Kunal ChughDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0009-0001-1558-4753
Megan E PaskDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.
Franz BaudenbacherDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.
Frederick R HaseltonDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0000-0003-4282-5222

Funding

Point-of-Care RT-PCR System to Inform COVID-19 and Respiratory Illness DecisionsR01AI157827 · NIAID · VANDERBILT UNIVERSITY · PI Frederick R Haselton, Jonathan E Schmitz · 2020 to 2026
$4.7M
East Tennessee Foundation N/ANIAID NIH HHS R01 AI157827NIH HHS RO1AI157827
6 · The paper itself

Abstract

In low-resource and point-of-care settings, traditional PCR often faces challenges of poor sample preparation, adverse environmental conditions, and long assay times. We have previously described a laboratory-based instrument to achieve "adaptive" PCR, a PCR thermocycling control system that replaces preset cycling times and temperatures with the optical monitoring of added L-DNA stereoisomers matching the sequences of the reaction primers and target. These L-DNA biosensors directly monitor DNA hybridization, compensating for ambient environmental conditions and poor sample preparation. This report describes instrument simplifications and a comparative evaluation of both direct photothermal and plasmonic laser heating to reduce the assay time to 15 min. Instrument performance was assessed using a split sample design to compare reaction performances of 1370 and 808 nm adaptive PCR heating modalities to a standard PCR instrument. Both the novel 1370 nm direct heating and the 808 nm plasmonic method achieved target amplification similar to the traditional PCR system within 15 min. However, a major disadvantage of 808 nm heating was nanorod optical interference that reduced the fluorescence signal from PCR probes and optical cycling components. Further characterization of the 1370 nm direct heating method found comparable limits of detection of 10

Indexed as

Biosensing TechniquesLasersPolymerase Chain ReactionDNAHot TemperatureDNAadaptive PCRmolecular diagnosticsphotothermal heatingplasmonicspoint of carerapid PCR

Identifiers

PMID40277572
PMCPMC12026111

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.