Evidence map›Paper›PMID 40276217›Full record

ArticleComputational and structural biotechnology journal2025

Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty.

Marie Theres Heller, Guenther Maderbacher, Marie Farina Schuster, Lina Forchhammer, Markus Scharf, Tobias Renkawitz, Stefano Pagano

Abstract read
In one paragraph

Article in Computational and structural biotechnology journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Marie Theres HellerDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Guenther MaderbacherDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Marie Farina SchusterDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Lina ForchhammerDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Markus ScharfDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Tobias RenkawitzDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Stefano PaganoDepartment of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate preoperative planning in total knee arthroplasty (TKA) is essential. Traditional manual radiographic planning can be time-consuming and potentially prone to inaccuracies. This study investigates the performance of an AI-based radiographic planning tool in comparison with manual measurements in patients undergoing total knee arthroplasty, using a retrospective observational design to assess reliability and efficiency. Methods: We retrospectively compared the Autoplan tool integrated within the mediCAD software (mediCAD Hectec GmbH, Altdorf, Germany), routinely implemented in our institutional workflow, to manual measurements performed by two orthopedic specialists on pre- and postoperative radiographs of 100 patients who underwent elective TKA. The following parameters were measured: leg length, mechanical axis deviation (MAD), mechanical lateral proximal femoral angle (mLPFA), anatomical mechanical angle (AMA), mechanical lateral distal femoral angle (mLDFA), joint line convergence angle (JLCA), mechanical medial proximal tibial angle (mMPTA), and mechanical tibiofemoral angle (mTFA).Intraclass correlation coefficients (ICCs) were calculated to assess measurement reliability, and the time required for each method was recorded. Results: The Autoplan tool demonstrated high reliability (ICC > 0.90) compared with manual measurements for linear parameters (e.g., leg length and MAD). However, the angular measurements of mLPFA, JLCA, and AMA exhibited poor reliability (ICC < 0.50) among all raters. The Autoplan tool significantly reduced the time required for measurements compared to manual measurements, with a mean time saving of 44.3 seconds per case (95 % CI: 43.5-45.1 seconds, Conclusion: AI-assisted tools like the Autoplan tool in mediCAD offer substantial time savings and demonstrate reliable measurements for certain linear parameters in preoperative TKA planning. However, the observed low reliability in some measurements, even amongst experienced human raters, suggests inherent challenges in the radiographic assessment of angular parameters. Further development is needed to improve the accuracy of automated angular measurements, and to address the inherent variability in their assessment.

Indexed as

Artificial IntelligenceAutomated PlanningIntraclass Correlation CoefficientMeasurement EfficiencyRadiographic MeasurementTotal Knee Arthroplasty

Identifiers

PMID40276217
PMCPMC12019206

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.