Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring.

Andrew J White, Cliff G Hammer, Matthew W Brenner, Larry A DeWerd, Kurt E Stump, Wesley S Culberson

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Andrew J WhiteDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.ORCID https://orcid.org/0000-0002-0980-0157
Cliff G HammerDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Matthew W BrennerDepartment of Radiation Oncology, Mercyhealth Javon Bea Hospital, Rockford, Illinois, USA.
Larry A DeWerdDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Kurt E StumpDepartment of Radiation Oncology, Mission Cancer Center, Asheville, North Carolina, USA.
Wesley S CulbersonDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeLiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre-treatment imaging kilovoltage (kV) beam and the megavoltage (MV) treatment beams. For low energy x-ray beams, where the photoelectric effect dominates, TLDs respond differently than tissue or water. An overresponse of up to 40% has been previously reported for lower-energy (kV) x-rays when calibrated to higher-energy (MV) beams. In this work, the response of TLDs to various cone beam computed tomography (CBCT) protocols with calibrations in clinical therapy beams (MV) is quantified.

methodsThree Varian OBI (Head, Thorax, and Pelvis) and three Elekta XVI (Fast Head and Neck, Fast Chest, and Fast Pelvis) CBCT protocols were investigated. For each protocol, TLDs were positioned on a tissue equivalent phantom at various distances extending out from the center of the imaging field. The response was determined by calibrating TLDs to a 6 MV photon beam.

resultsThe maximum in-field TLD response ranged from 0.82 to 4.80 and 0.06 to 2.69 cGy for Varian OBI and Elekta XVI protocols, respectively. The out-of-field CBCT response dropped exponentially from the field edge. Calculated uncertainties were generally less than 3% (k = 1), with exceptions along the edge of the CBCT field (6%) and at the most distal TLD positions (34%).

conclusionsUsing the measured TLD responses to CBCT protocols with an MV calibration, the therapeutic dose can be isolated. The therapeutic dose can then be compared to predictions from the treatment planning system (TPS), allowing for more accurate dose verification for complex treatment setups and patients with CIEDs. The CBCT response can change the reported therapeutic dose by up to 2.5%.

Indexed as

Cone-Beam Computed TomographyHead and Neck NeoplasmsPhantoms, ImagingRadiotherapy Planning, Computer-AssistedThermoluminescent DosimetryCalibrationHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedCBCTCIEDdose verificationin vivo dosimetryTLD