Evidence map›Paper›PMID 40275243›Full record

ArticleBMC oral health2025

Evaluation of the occlusal trueness among 3-Dimensionally printed CAD-CAM complete dentures with different socket designs and teeth splinting assemblies.

Rowan Mohamed Abdelsadek Mohamed Sallam, Nayrouz Adel Metwally, Mohamed Moataz Khamis

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rowan Mohamed Abdelsadek Mohamed SallamDepartment of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Nayrouz Adel MetwallyDepartment of Prosthodontics, Faculty of Dentistry, Alexandria University, Champollion St, Alexandria, Azarita, Egypt. nayrouz.metwally@alexu.edu.eg.
Mohamed Moataz KhamisDepartment of Prosthodontics, Faculty of Dentistry, Alexandria University, Champollion St, Alexandria, Azarita, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTeeth sockets of the 3 dimensionally (3D) printed denture base can be designed in different shapes. Denture teeth can also be printed separately or splinted. However, the effect of the socket forms and the denture teeth splinting on the teeth displacement has not been clarified in literature. The goal of this study is to evaluate and compare the effect of different socket designs and teeth splinting assemblies on the trueness of the teeth positions of 3D-printed complete dentures.

methodsA total of 80 maxillary dentures were fabricated for this study. All dentures were designed by using a computer-aided design (CAD) software program (exocad software; exocad GmbH). Two designs for the teeth sockets of the denture base were used in this study: socketed design and thimble design. Teeth were also aligned in 3 forms: One-unit splinted design, 3-unit splinted design or unsplinted denture teeth. The dentures were divided into 8 groups (n = 10) according to the design used. Group I (unsplinted teeth/socketed base), Group II (unsplinted teeth/thimbled base), Group III (1-unit splinted teeth/socketed base), Group IV (1-unit splinted teeth/thimble base), Group V (3-unit splinted teeth/socketed base), Group VI (3-unit splinted teeth/thimble base), Group VII (Semi conventional pack and press), Group VIII (Monoblock). Groups from I -VII were 3D-printed by using SLA 3D-printer (Form 2; Formlabs Inc.) (Denture teeth A2, Formlabs) (Denture base LP, Formlabs). Group VIII was 3D-printed from castable wax resin (Castable wax, Formlabs Inc.) then flasked in a conventional manner. All dentures were then scanned by using a desktop scanner (Medit T710, Medit Corp) and saved as STL files. To evaluate the accuracy of the teeth position the CAD design file was imported and set as the reference data to which all scanned dentures were matched and compared by using (Geomagic Control X; 3D system Inc) The Shapiro-Wilk test of normality was used. Data was not normally distributed. Comparison between the study groups was done by using Krauskal Wallis test. Significance level was set at (P <.05).

resultsThe results showed a significant difference in teeth deviation values among the groups (P <.05). The lowest deviation values were reported in group VII across the overall denture teeth (0.104), anterior denture teeth (0.104) and posterior denture teeth (0.104), regarding the overall denture teeth and the posterior denture teeth, a statistically significant difference was identified when group VII was compared to all other groups. Regarding the anterior denture teeth, a non-statistically significant difference was identified when the group VII is compared to the group III. Higher deviation values were identified in the incisors as compared to the canines. However, deviation values were variable when the premolars and molars were compared.

conclusionsThe results of the present study reported that median deviations were in the range of (0.104-0.282) mm, recommending the clinical choice of group VII followed by group III to provide the highest occlusal trueness.

Indexed as

Computer-Aided DesignDental OcclusionDenture, CompleteDenture, Complete, UpperDenture DesignPrinting, Three-DimensionalHumansTooth, Artificial3D PrintingAccuracyCAD-CAMComplete dentures

Identifiers

PMID40275243
PMCPMC12023419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.