Evidence map›Paper›PMID 40273174›Full record

SynthesisPloS one2025

Maternal complication of instrumental vaginal delivery and its associated factors: Systematic review and meta-analysis.

Hinsermu Bayu Abdi, Elias Bekele Wakwaya, Beyene Sisay Damtew, Beker Ahmed Hussen, Teresa Kisi Beyen

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hinsermu Bayu AbdiDepartment of Midwifery, College of Health Sciences, Arsi University, Assela, Ethiopia.ORCID 0000-0002-9065-7086
Elias Bekele WakwayaDepartment of Midwifery, College of Health Sciences, Arsi University, Assela, Ethiopia.ORCID 0000-0001-5520-4308
Beyene Sisay DamtewDepartment of Midwifery, College of Health Sciences, Arsi University, Assela, Ethiopia.
Beker Ahmed HussenDepartment of Midwifery, College of Health Sciences, Arsi University, Assela, Ethiopia.
Teresa Kisi BeyenSchool of Public Health, College of Health Sciences, University of Gondar, Gondar, Ethiopia.ORCID 0000-0002-2168-6887

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile instrumental vaginal delivery is generally a safe procedure, but it is associated with significant risks for both the mother and the newborn in developing countries. However, burden of maternal instrumental delivery complications and its predictors in Ethiopia is highly varied and there isn't data that indicate nation-level cumulative evidence. Therefore, this study aimed to assess pooled prevalence of maternal complication related to instrumental vaginal delivery and its associated factors among mothers who underwent instrumental vaginal delivery in Ethiopia.

methodsIn this study, we conducted a search on PubMed, Scopus, Cochrane library, HINARI, and Google Scholar academic databases for studies published until August 2024. Keywords such as instrumental delivery, forceps, vacuum, complication, factors and Ethiopia were used to access literatures from the databases. For quality assessment and data extraction, The Joanna Briggs Critical Appraisal Tools and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were utilized. Random-effect model was used to calculate the pooled prevalence of maternal complication of instrumental vaginal delivery. Subgroup analyses were also conducted to explore potential heterogeneity. The publication bias was assessed using Funnel plot and Egger's.

resultsA total of 12 studies with 3745 study participants were participated in the present meta-analysis. The pooled prevalence of maternal complication of instrumental vaginal delivery was 21% (95% CI, 15.0%-28.0%). The prevalence of maternal complication was significantly different among studies conducted between ([2015-2020), and those conducted between [2020 and 2024]. Lowest (14%) in studies conducted before 2020 and highest (26%) among studies conducted 2020 and after (P-value<0.001). Type of instrument (AOR: 1.99, 95% CI: 1.37-2.90), episiotomy status (AOR: 3.49, 95% CI: 2.12-5.76), birthweight (AOR: 3.06, 95% CI: 1.88-4.97) and parity (AOR = 2.96, 95%CI: 1.80-4.85) were the factors associated with maternal complication of instrumental vaginal delivery.

conclusionOur study shows that approximately one in five mothers who underwent instrumental vaginal delivery develop serious maternal complication. Type of the instrument, episiotomy status, birthweight and parity were important predictors of the maternal complication of instrumental vaginal delivery. Effective evaluation of indication, contra indication and precondition for each instrument helps to prevent the maternal complication of instrumental vaginal delivery.

trial registrationRegistered in PROSPERO with ID: CRD42022366360.

Indexed as

Delivery, ObstetricExtraction, ObstetricalObstetric Labor ComplicationsEthiopiaFemaleHumansObstetrical ForcepsPregnancyPrevalenceRisk Factors

Identifiers

PMID40273174
PMCPMC12021129

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.