Evidence map›Paper›PMID 40267126›Full record

ArticlePloS one2025

Point-of-care testing of hyponatremia and hypernatremia levels: An optoplasmonic biosensing approach.

Abdullah Mohammad Tanvirul Hoque, Abrar Islam, Firoz Haider, Rifat Ahmmed Aoni, Rajib Ahmed

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abdullah Mohammad Tanvirul HoqueThe Wyant College of Optical Sciences, The University of Arizona, Tucson, Arizona, United States of America.
Abrar IslamDepartment of Electrical and Electronic Engineering, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalganj, Bangladesh.ORCID 0000-0002-3270-9837
Firoz HaiderFaculty of Science & Technology, Charles Darwin University, Darwin, Northern Territory, Australia.
Rifat Ahmmed AoniThe Mork Family Department of Chemical Engineering and Materials Science, University of Southern California, Los Angeles, California, United States of America.
Rajib AhmedSchool of Medicine, Stanford University, Palo Alto, California, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the human body, sodium ion (Na+) is the principal extracellular cation and its imbalance in blood or lymph results in either hyponatremia or hypernatremia conditions. Any of these scenarios have fatal effects on a patient's health over time. However, the existing technologies limit quick point-of-care (POC) testing options. To overcome the challenges associated with prompt diagnosis, we proposed a photonic crystal fiber (PCF) based surface plasmon resonance (SPR) sensor for in situ rapid testing of Na+ ion levels in patient's blood samples. A unique PCF sensor with a modified square lattice is engineered to achieve a propagation-controlled core that permits enhanced control over wave guidance resulting in improved sensing performance. Plasmonically active conducting indium tin oxide (ITO) is used to omit the limitations that arise from undesired oxidation with time and to enable higher spectral tunability. The finite element method (FEM) is used to perform the numerical analysis on performance and all sensor parameters are optimized to ensure the best sensing outcome. The structural asymmetry-induced birefringence enforced a superior y-polarized sensing response compared to that of the x-polarized mode for the proposed sensor, where it proffers the highest wavelength sensitivity of 15,157 nm/RIU with a detection resolution of 6.61 ×  10-6 RIU. Additionally, the sensor exhibits a maximum amplitude sensitivity of 470 RIU-1 and an outstanding figure of merit (FOM) of 171 RIU-1. Due to the high sensitivity and resolution, we infer that the proposed sensor will be a promising POC alternative to the conventional serum electrolyte panels used in present medical practice.

Indexed as

Biosensing TechniquesHypernatremiaHyponatremiaPoint-of-Care TestingHumansSodiumSurface Plasmon ResonanceTin Compoundsindium tin oxideSodiumTin Compounds

Identifiers

PMID40267126
PMCPMC12017493

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.