Testing of a novel automated point-of-care analyzer for blood ammonium monitoring in a clinical setting.

Beatriz Rebollo-Calderón, Antonio Calvo-López, Aida Ormazábal, Rafael Artuch, Javier Rosell-Ferrer, Julian Alonso-Chamarro, Mar Puyol

Abstract readValidation Study
In one paragraph

Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Beatriz Rebollo-CalderónGroup of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, Bellaterra, Barcelona, 08193, Spain.
Antonio Calvo-LópezInstitut de Recerca Sant Joan de Déu, Passeig de Sant Joan de Déu, 2, Esplugues de Llobregat, Barcelona, 08950, Spain.
Aida OrmazábalInstitut de Recerca Sant Joan de Déu, Passeig de Sant Joan de Déu, 2, Esplugues de Llobregat, Barcelona, 08950, Spain.
Rafael ArtuchInstitut de Recerca Sant Joan de Déu, Passeig de Sant Joan de Déu, 2, Esplugues de Llobregat, Barcelona, 08950, Spain.
Javier Rosell-FerrerCentre de Recerca en Enginyeria Biomèdica (CREB), Universitat Politécnica de Catalunya (UPC), Campus Diagonal Sud, Edifici H., Av. Diagonal 647, Barcelona, Spain.
Julian Alonso-ChamarroGroup of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, Bellaterra, Barcelona, 08193, Spain.
Mar PuyolGroup of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, Bellaterra, Barcelona, 08193, Spain. MariaDelMar.Puyol@uab.es.

Funding

Agència de Gestió d'Ajuts Universitaris i de Recerca 2021SGR00124Instituto de Salud Carlos III DTS18/00075Instituto de Salud Carlos III DTS18/00104Ministerio de Economía y Competitividad CTQ2017-85011-RMinisterio de Economía y Competitividad PDC2021-121558-100Ministerio de Economía y Competitividad PID2020-117216RB
6 · The paper itself

Abstract

Certain diseases are marked by elevated ammonium levels in the blood, a condition known as hyperammonemia. Prompt detection and medical intervention are crucial to prevent potentially fatal outcomes. Therefore, ammonium levels should be monitored regularly, typically in referral hospitals where specialized and costly equipment is available. Although compact commercial devices are available for this purpose, none of them meet all the technical and analytical requirements needed for direct blood analysis, and current reported strategies have not been validated with enough samples to confirm results reliably. We present a robust and reliable automated point-of-care (POC) analyzer for the potentiometric determination of ammonium in blood. Comprising three computer-controlled modules-fluid management, detection, and data acquisition and transmission-this system combines portability, ease of use, and affordability. It can directly measure untreated blood samples, significantly reducing analysis time. Fully automated, it operates unsupervised with minimal lab personnel intervention. Analytical quality parameters include 5% RSD repeatability (n = 8), a limit of detection of 24 μM, a working range of 30-1000 µM and a sample volume of 215 µL. Successfully implemented in a hospital for 2 months, it analyzed 238 blood samples in parallel with the hospital's reference method showing comparable results (paired t-test, Passing-Bablok regression and Bland-Altman Plot) and randomly distributed errors, with a 4% accuracy calculated as mean error. Results indicate the POC analyzer effectiveness and reliability in a clinical setting compared to currently reported or commercially available equipment, being suitable for bedside monitoring of conditions associated with hyperammonemia in healthcare centers, including emergency rooms and clinics in developing countries.

Indexed as

Ammonium CompoundsHyperammonemiaMonitoring, PhysiologicPoint-of-Care TestingPotentiometryComputer-Aided DesignHumansLimit of DetectionAmmonium CompoundsAmmonium selective electrodesHyperammonemiaInborn error of metabolismPoint-of-carePotentiometry

Identifiers

PMID40266320
PMCPMC12122597

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.