Testing of a novel automated point-of-care analyzer for blood ammonium monitoring in a clinical setting.
Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Certain diseases are marked by elevated ammonium levels in the blood, a condition known as hyperammonemia. Prompt detection and medical intervention are crucial to prevent potentially fatal outcomes. Therefore, ammonium levels should be monitored regularly, typically in referral hospitals where specialized and costly equipment is available. Although compact commercial devices are available for this purpose, none of them meet all the technical and analytical requirements needed for direct blood analysis, and current reported strategies have not been validated with enough samples to confirm results reliably. We present a robust and reliable automated point-of-care (POC) analyzer for the potentiometric determination of ammonium in blood. Comprising three computer-controlled modules-fluid management, detection, and data acquisition and transmission-this system combines portability, ease of use, and affordability. It can directly measure untreated blood samples, significantly reducing analysis time. Fully automated, it operates unsupervised with minimal lab personnel intervention. Analytical quality parameters include 5% RSD repeatability (n = 8), a limit of detection of 24 μM, a working range of 30-1000 µM and a sample volume of 215 µL. Successfully implemented in a hospital for 2 months, it analyzed 238 blood samples in parallel with the hospital's reference method showing comparable results (paired t-test, Passing-Bablok regression and Bland-Altman Plot) and randomly distributed errors, with a 4% accuracy calculated as mean error. Results indicate the POC analyzer effectiveness and reliability in a clinical setting compared to currently reported or commercially available equipment, being suitable for bedside monitoring of conditions associated with hyperammonemia in healthcare centers, including emergency rooms and clinics in developing countries.