ArticleScientific reports2025
Optimal distributed generation placement and sizing using modified grey wolf optimization and ETAP for power system performance enhancement and protection adaptation.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- ELLS-NSBA three-stage framework for optimal DG/SC placement and EV integration in distribution networks.Scientific reports · 2026Article
- Integrated machine learning forecasting and grey wolf optimization for optimal operation of virtual power plants in smart distribution networks.Scientific reports · 2026Article
- Article
- Congestion management using monarch butterfly optimization in restructured power system.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The integration of distributed generation (DG) units into electricity distribution networks (EDNs) is a key strategy for enhancing system performance, improving power quality, and increasing network reliability through effective voltage control. This paper presents a hybrid technique that integrates a modified grey wolf optimization (MGWO) algorithm, implemented in MATLAB, with the electrical transient and analysis program (ETAP) software for security analysis to achieve the optimal locations and sizing of DG units under protection adaptation. The proposed technique focuses on minimizing active (APL) and reactive (RPL) power losses, improving voltage stability (VS) and investigating the effects of fault current variations on the protection system to ensure its adaptability to the integration of DG units. The MGWO algorithm is an improved version of the conventional GWO algorithm, which is based on a hierarchical model inspired by the social behavior of grey wolves. MGWO is modified by the addition of adaptive weights and dynamic circling mechanisms, which improve the balance between exploration (searching for new regions of the solution space) and exploitation (improving known solutions). These modifications enable the wolves to adjust their position dynamically; thus, avoiding premature convergence and allowing them to escape local optima. The MGWO expands on the GWO with adaptive mechanisms that prevents it from becoming trapped in the local minima, yielding faster convergence time, better accuracy of solution, and increased immunity and robustness to solving optimization problems that are complex and multimodal. The effectiveness of the proposed approach is evaluated by simulations performed on the IEEE 33-bus test system and a large scale 114-bus distribution network to determine its reliability for different network sizes. The findings indicate that the optimal DG placement in the 33-bus system results in a 69.7% decrease in average power loss, a 69.6% decrease in real power loss, and a 7.3% enhancement in voltage stability. In the 114-bus system, APL and RPL decreased by 65.2% and 64.9%, respectively, accompanied by a 6.5% enhancement in VS. In addition, ETAP analysis was performed using Newton-Raphson (NR) for load flow analysis to assess the effects of DG integration at different capacity levels. The results indicate that the integration of DG units has a considerable effect on fault current behaviour, with the maximum fault current (I_max) increasing by up to 21.5%, while the minimum fault current (I_min) shows considerable fluctuations, requiring changes in protection strategies to manage altered fault current levels. The comparison of the results to the traditional and advanced metaheuristic algorithms confirm that the proposed technique achieved a higher power loss minimization while maintaining the system stability. Furthermore, the proposed MGWO-ETAP offers a global solution by combining DG placement and sizing optimization with adaptive protection controls, ensuring reliable and efficient DG integration in complex power systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.