Evidence map›Paper›PMID 40263300›Full record

ArticleMicrosystems & nanoengineering2025

Multi-DoF AlN-on-SOI BAW MEMS resonators with coated ZIF-8 for gas sensing application.

Linlin Wang, Yuan Wang, Max Tietze, Bernardo Pereira Madeira, Rui P Martins, Pui-In Mak, Nicolas Chanut, Divya Rajagopal, Masaya Sugihara, Rob Ameloot and 1 more

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Linlin WangESAT-MNS, KU Leuven, Leuven, 3001, Belgium.
Yuan WangInstitute of Microelectronics (AMSV), University of Macau, Taipa, Macau, China. yuanwang@um.edu.mo.ORCID http://orcid.org/0000-0003-3814-4520
Max TietzeCIT-cMACS, KU Leuven, Leuven, 3001, Belgium.
Bernardo Pereira MadeiraESAT-MNS, KU Leuven, Leuven, 3001, Belgium.
Rui P MartinsInstitute of Microelectronics (AMSV), University of Macau, Taipa, Macau, China.
Pui-In MakInstitute of Microelectronics (AMSV), University of Macau, Taipa, Macau, China.
Nicolas ChanutCIT-cMACS, KU Leuven, Leuven, 3001, Belgium.
Divya RajagopalESAT-MNS, KU Leuven, Leuven, 3001, Belgium.
Masaya SugiharaCIT-cMACS, KU Leuven, Leuven, 3001, Belgium.
Rob AmelootCIT-cMACS, KU Leuven, Leuven, 3001, Belgium.
Chen WangESAT-MNS, KU Leuven, Leuven, 3001, Belgium. chen.wang@kuleuven.be.

Funding

Macau University of Science and Technology Foundation (MUST Foundation) 004/2023/KSLMacau University of Science and Technology Foundation (MUST Foundation) 004/2023/SKLMacau University of Science and Technology Foundation (MUST Foundation) 0087/2023/IITP2Macau University of Science and Technology Foundation (MUST Foundation) 0087/2023/ITP2
6 · The paper itself

Abstract

This paper explored the practical utility of gas sensing applications based on the multi-degree-of-freedom (Multi-DoF) bulk acoustic wave (BAW) resonant sensors, including 1, 2, and 3-DoF devices, where piezoelectric actuation and sensing methods were adopted. Zeolitic imidazolate framework-8 (ZIF-8) was chosen for the adsorption and desorption of the ethanol vapor, thereby facilitating the gas sensing mechanism and introducing the external mass changes to the multi-DoF resonating system. Similar to conventional quartz crystal microbalance (QCM) gas sensors, the frequency shift of all the devices (1, 2, and 3-DoF devices) was tracked to characterize the sensitivity. Besides, for the 2 and 3-DoF devices, the amplitude ratio (AR) change was also recorded and observed with an enhancement in performance. Compared with the state-of-the-art gas sensor based on 2-DoFcapacitively coupled resonators, the presented devices achieved better Q factor in air, stability, and resolution in terms of both frequency shifts and AR changes. The dominant mass change (dominant stiffness change in the state-of-the-art) of the proposed resonant devices matched well with the theoretical mass sensing principle, which is both predictable and crucial for the accurate modeling of the practical mass sensor. Furthermore, a lower ethanol vapor concentration from 0.1% to 2% was successfully detected by the proposed 2-DoF device, demonstrating even better sensing performance than that of the state-of-the-art.

Identifiers

PMID40263300
PMCPMC12015448

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.