Evidence map›Paper›PMID 40261646›Full record

ArticleJournal of synchrotron radiation2025

Method for visualizing detailed profiles of synchrotron X-ray beams using diamond-thin films and silicon drift detectors.

Togo Kudo, Shinji Suzuki, Mutsumi Sano, Toshiro Itoga, Hiroyasu Masunaga, Shunji Goto, Sunao Takahashi

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Togo KudoJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.ORCID 0000-0001-5771-6040
Shinji SuzukiJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.ORCID 0000-0002-6858-1927
Mutsumi SanoJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.
Toshiro ItogaJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.ORCID 0000-0002-5887-3707
Hiroyasu MasunagaJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.
Shunji GotoJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.ORCID 0000-0003-0345-7025
Sunao TakahashiJapan Synchrotron Radiation Research Institute, Sayo-cho 1-1-1, Sayo-gun, Hyogo 679-5198, Japan.ORCID 0000-0002-7571-8936

Funding

Japan Society for the Promotion of Science 22K12668
6 · The paper itself

Abstract

Contamination from nearby bending magnet radiation hinders precise and accurate determination of the true beam center of undulator radiation. To solve this problem, a semi-nondestructive method was developed to visualize the detailed profile of a synchrotron radiation beam by using a thin diamond film as a scatterer. As the beam passed through the diamond film, scattered X-rays were imaged using a pinhole camera and measured with a two-dimensional silicon drift detector (SDD) scan. With this configuration, the beam center was accurately determined by visualizing the radiation pattern distribution for each energy level of a pink X-ray beam within an aperture size of 1.5 mm × 1.5 mm, shaped by a front-end slit (FES) positioned upstream of the monochromator. Additionally, by scanning the FES in two dimensions with a reduced aperture of 0.4 mm × 0.4 mm, energy-resolved images were successfully obtained using the SDD at a fixed position. These images revealed the profile of undulator radiation over a broad area (with an aperture extending up to 4 mm) in a pre-slit positioned upstream of the FES, demonstrating good alignment with SPECTRA calculations. This method effectively eliminates contamination from nearby bending magnet radiation, a significant issue in previous approaches, enabling a direct and highly accurate determination of the true beam center.

Indexed as

diffraction-limited storage ringsfront-end slitssilicon drift detectorsundulatorsX-ray beam position monitorsX-ray beam profile monitors

Identifiers

PMID40261646
PMCPMC12067321

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.