Evidence map›Paper›PMID 40260755›Full record

ArticleJournal of applied clinical medical physics2025

Fast, automated optimization of virtual monoenergetic images with the dual-energy image synthesizer for cone-beam CT.

Andrew Keeler, Jason Luce, Mathias Lehmann, John C Roeske, Hyejoo Kang

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andrew KeelerDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Jason LuceDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Mathias LehmannVarian Imaging Laboratory, Baden, Switzerland.
John C RoeskeDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Hyejoo KangDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.ORCID https://orcid.org/0000-0002-4433-0939

Funding

Markerless Motion Tracking of Lung Tumors Using Dual Energy ImagingR01CA207483 · NCI · LOYOLA UNIVERSITY CHICAGO · PI LEHMANN, MATHIAS, ROESKE, JOHN · 2017 to 2025
$2.2M
National Cancer Institute of the National Institutes of Health R01-CA207483NCI NIH HHS R01 CA207483
6 · The paper itself

Abstract

backgroundDual-energy cone-beam CT (DE-CBCT) has become subject of recent interest due to the ability to produce virtual monoenergetic images (VMIs) with improved soft-tissue contrast and reduced nonuniformity artifacts. However, efficient production and optimization of VMIs remains an under-explored part of DE-CBCT's application. PURPOSE: This work reports on the creation of DISC (dual-energy image synthesizer for CBCT), a newly developed, open-source user interface to efficiently produce and optimize VMIs with the eventual goal of clinical application.

methodsTwo sets of CBCT scans of a Catphan 604 phantom were acquired sequentially (80 and 140 kVp) using the on-board imager of a commercial linear accelerator. Material decomposition into aluminum (Al) and polymethyl-methylacrylate (PMMA) basis materials in the projection-domain and reconstruction with the Feldkamp-Davis-Kress (FDK) algorithm of basis material images were performed in the open-source Tomographic Iterative GPU-based REconstruction (TIGRE) Matlab toolkit. Using DISC, a series of VMIs were generated via linear combinations of the basis material images without reconstructing individual VMIs at different energies. Hounsfield units (HU) were computed using an energy-dependent fit over the range of 20-150 keV. VMI energies that maximized contrast-to-noise ratio (CNR) for various materials and minimized nonuniformity artifacts were determined with 1 keV precision.

resultsOptimal CNR values for all material inserts ranged from 55 to 62 keV, showing an average CNR enhancement of 25% over the polychromatic images. Optimal uniformity is observed at 65 keV. Computed HUs show good agreement with theoretical values, with root-mean-squared error of 16 HU across the range of energies and materials.

conclusionA spectrum of VMIs from DE-CBCT was efficiently produced with 1 keV precision using DISC. Optimal energies for both soft tissue contrast and nonuniformity reduction were quickly computed with high precision. Future work will expand DISC to generate other DE-derived image types and will explore the acquisition and optimization of DE patient images.

Indexed as

AlgorithmsCone-Beam Computed TomographyImage Processing, Computer-AssistedPhantoms, ImagingRadiotherapy Planning, Computer-AssistedArtifactsHumansParticle AcceleratorsRadiotherapy DosageRadiotherapy, Intensity-Modulatedcone beam CTdual‐energyvirtual monoenergetic images

Identifiers

PMID40260755
PMCPMC12148776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.