Trial reportClinical orthopaedics and related research2025
Standardized Intraoperative Robotic Laxity Assessment in TKA Leads to No Clinically Important Improvements at 2 Years Postoperatively: A Randomized Controlled Trial.
Trial report in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Comparative pain relief and functional outcomes following robotic-assisted versus conventional total knee arthroplasty: a GRADE-assessed meta-analysis with meta-regression of randomized controlled trials.Journal of robotic surgery · 2026Pooled it
- Asia-Pacific expert consensus on robotic-assisted hip and knee arthroplasty.Arthroplasty (London, England) · 2026Review
- Alignment and/or ligament balancing? Towards truly personalized total knee arthroplasty-A narrative review.Journal of experimental orthopaedics · 2026Review
- Comparative analysis of HURWA versus MAKO robotic-assisted TKA: a prospective cohort study of surgical accuracy and clinical outcomes.Journal of robotic surgery · 2026Article
- Article
- CORR Insights®: Standardized Intraoperative Robotic Laxity Assessment in TKA Leads to No Clinically Important Improvements at 2 Years Postoperatively: A Randomized Controlled Trial.Clinical orthopaedics and related research · 2025Article
- Manual Stress and Gap Spacer Systematically Underestimate Intraoperative Joint Gaps Compared with a Tensor Device in Robotic-Assisted Total Knee Arthroplasty.JB & JS open accessArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundJoint stability is a major factor associated with success after TKA. However, most assistive technologies, such as robotic-assisted TKA, do not incorporate a standardized laxity assessment. To address this gap, we opted to perform a randomized controlled trial comparing the results of a manual versus a robot-assisted TKA system with standardized laxity assessment. QUESTIONS/PURPOSES: (1) Does robot-assisted TKA with a standardized laxity assessment provide superior patient-reported outcomes compared with conventional TKA with a manual tensioner, and does it result in a higher percentage of patients achieving the patient acceptable symptom state (PASS) thresholds 2 years after surgery? (2) Does robot-assisted TKA with a standardized laxity assessment provide different coronal alignment or coronal laxity compared with conventional TKA with a manual tensioner after surgery?
methodsThis was a prospectively registered randomized trial performed at a single center in Belgium. Patients with end-stage knee osteoarthritis unresponsive to conservative treatment were eligible. Exclusion criteria included severe deformity, limited ROM, prior fractures, infection, ligament insufficiency, and neurologic conditions. Between September 2020 and August 2022, we randomized 60 patients to receive TKA either with a manual tensiometer (n = 30) or a robotic-assisted TKA with an imageless system using a standardized laxity system (distraction of the tibiofemoral joint with 80N throughout ROM; n = 30). Of those, 100% (30 of 30) and 90% (27 of 30) of patients were available for follow-up at 2 years in the robotic-assisted and conventional groups, respectively. In both groups, a posterior stabilized implant was used. Patient-reported outcome measures (Knee Society Score [KSS], WOMAC, and 5-level EuroQol 5-domain scores) were obtained preoperatively and at 2 years postoperatively. Coronal alignment and implant position were evaluated on full-leg weightbearing radiographs. Stress radiographs were obtained to assess coronal laxity in 10° of flexion. There were no differences between the groups in baseline characteristics of age, BMI, side, gender, hip-knee-ankle axis, ROM, or patient-reported outcome measures. To account for multiple comparisons in this study, a Bonferroni correction was applied. All differences between both groups were evaluated considering minimum clinically important difference values for patients who have undergone TKA. The power analysis indicated 80% power to detect a clinically meaningful difference of 9.7 points in KSS function score, with an alpha of 0.05.
resultsWe found no clinically important differences in patient-reported outcomes 2 years after surgery between the conventional and the robotic group (for example, the KSS function score in those groups was 66 ± 20 versus 74 ± 24, respectively, mean difference 8 [95% confidence interval (CI) -3 to 21]; p = 0.18), and no difference in the proportion of patients in those groups who achieved the PASS on any outcomes score (for example, the percentage of patients achieving the PASS for the WOMAC was 4% [1 of 27] versus 3% [1 of 30], respectively, OR 0.9 [95% CI 0 to 15]; p > 0.99). Likewise, there were no differences in postoperative hip-knee-ankle axis between the conventional and the robotic groups, respectively (1° ± 2° varus versus 1° ± 3° varus; p > 0.99) or in coronal-plane laxity (6° ± 3° versus 7° ± 2° in the conventional cohort; p = 0.73).
conclusionBased on the absence of clinically important differences in outcome scores or any differences in the proportion of patients who achieved the PASS on those scores (as well as the absence of meaningful differences in alignment or soft tissue tension), we recommend against the routine use of robotic TKA with objectified laxity assessment because it adds costs and time to these procedures without delivering benefits that patients might perceive. Future studies might, however, be able to identify patient-specific laxity targets to improve patient outcomes. LEVEL OF EVIDENCE: Level I, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.