Evidence map›Paper›PMID 40256668›Full record

ArticleJournal of experimental orthopaedics2025

Femoral resection accuracy and precision in manual caliper-verified kinematic alignment total knee arthroplasty.

David Forrest Scott, Emma N Horton

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

David Forrest ScottSpokane Joint Replacement Center, Inc. Spokane Washington USA.ORCID 0000-0002-3194-1204
Emma N HortonSpokane Joint Replacement Center, Inc. Spokane Washington USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The accuracy and precision of bone resections in total knee arthroplasty (TKA) are essential to avoid poor implant positioning, which can lead to component wear, pain, and instability, reducing patient satisfaction and implant survivorship. Technology-assisted TKA techniques aim to improve accuracy but come with added costs, increased operative time, and varying success in clinical outcomes. Caliper-verified kinematic alignment (KA) attempts to restore the joint line by precisely measuring resections to equal implant thickness. We evaluated the accuracy and precision of caliper-verified KA-TKA performed with manual instruments. We hypothesised that this technique would achieve high accuracy and precision, with an average absolute difference between actual and target distal and posterior femoral resection measurements of ≤ 0.5 mm. Methods: 385 consecutive patients underwent primary unrestricted caliper-verified KA-TKA with manual instrumentation. The thickness of the distal medial (DM), distal lateral (DL), posterior medial (PM) and posterior lateral (PL) femoral condyle resections were measured with a caliper and compared to a target determined by the degree of cartilage loss, saw blade kerf, and femoral component thickness. Results: The mean differences between the resected and target thicknesses for DM, DL, PM and PL femoral resections were 0.1 ± 0.2 mm, 0.1 ± 0.3 mm, 0.3 ± 0.5 mm and 0.2 ± 0.4 mm, respectively (mean ± std. dev.). Most femoral resections were within 0.5 mm of the target-97.7%, 94.5%, 85.7% and 89.4% of DM, DL, PM and PL resections, respectively. Conclusion: Manual caliper-verified KA-TKA achieved highly accurate and precise femoral resections with absolute differences from target that averaged 0.175 mm. This simple, logical, efficient, and reproducible surgical technique may be an option for surgeons contemplating the use of technology-assisted options, such as patient-specific instrumentation or robotic arm-assisted TKA, and surgeons without access to such technologies. Level of Evidence: Level II.

Indexed as

kinematic alignmentpatient‐specific instrumentationrobotic arm‐assistedtotal knee arthroplasty

Identifiers

PMID40256668
PMCPMC12006286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.