Evidence map›Paper›PMID 40256649›Full record

ReviewMedical devices (Auckland, N.Z.)2025

Evaluating the Impact of Smart Infusion Pump Interoperability on Reducing Medication Administration Errors: A Systematic Literature Review.

Eric P Borrelli, Julia D Lucaci, Nicole S Wilson, Ashley Taneja, Mia Weiss, Idal Beer

Abstract readReview
In one paragraph

Review in Medical devices (Auckland, N.Z.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Theoretical applications of artificial intelligence in smart infusion pump technology: Expert panel insights.American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2026
    Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eric P BorrelliHealth Economics and Outcomes Research, MMS, Becton, Dickinson and Company, San Diego, CA, USA.ORCID 0000-0002-9941-9893
Julia D LucaciHEOR Strategic Planning; Becton, Dickinson and Company, Franklin Lakes, NJ, USA.ORCID 0009-0004-9002-4600
Nicole S WilsonMedical Affairs, MMS, Becton, Dickinson and Company, San Diego, CA, USA.
Ashley TanejaHEOR Strategic Planning; Becton, Dickinson and Company, Franklin Lakes, NJ, USA.ORCID 0000-0003-4853-7811
Mia WeissHEOR Strategic Planning; Becton, Dickinson and Company, Franklin Lakes, NJ, USA.
Idal BeerMedical Affairs, MMS, Becton, Dickinson and Company, San Diego, CA, USA.ORCID 0000-0001-6140-1017

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Medication administration errors remain a persistent issue in the US healthcare system, impacting patient safety and leading to worsened outcomes, including increased mortality. Smart infusion pump interoperability with electronic health records (EHRs) has the potential to reduce intravenous (IV) medication administration errors. Smart Infusion pumps safely deliver IV medications using drug libraries that set standard dosing limits. Interoperability is their ability to wirelessly connect to EHRs to receive medications orders directly minimizing error-prone manual programming steps. However, despite being implemented over a decade ago, its real-world impact remains largely underexplored. Methods and Materials: A systematic literature review (SLR) of PubMed/Medline and Embase in November 2024 identified peer-reviewed studies assessing medication administration errors pre- and post- interoperability implementation in the inpatient hospital setting. The primary outcome measured error types directly impacted by interoperability. The secondary outcome assessed the cumulative reduction in medication administration errors. Results: Three studies met the inclusion criteria, spanning general community hospitals, pediatric facilities, and intensive care units (ICUs). For the primary outcome of assessing medication administration errors impactable by interoperability, interoperability implementation resulted in a 15.4% to 54.8% reduction in specific medication administration errors. For the secondary outcome of all medication administration errors, the cumulative reductions in medication administration errors post-implementation ranged from 21.2% to 90.5%, with variability influenced by baseline compliance, study setting, and patient populations. Conclusion: Smart infusion pump interoperability demonstrated consistent potential to enhance medication safety by addressing key error types and reducing cumulative errors in real-world settings. However, future research is needed to assess its impact on adverse drug events, clinician workflows, and patient outcomes. These findings underscore the importance of tailored implementation strategies to maximize interoperability's effectiveness in improving patient safety.

Indexed as

auto programminginfusion errorsinteroperabilitymedication administration errorspreventable adverse eventssmart infusion pump

Identifiers

PMID40256649
PMCPMC12009041

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.