Evidence map›Paper›PMID 40256186›Full record

ArticleJournal of medical physics

Focused Ultrasound Sonications of Tumor Model in Head Phantom under MRI Monitoring: Effect of Skull Obstruction on Focal Heating.

Anastasia Antoniou, Antreas Chrysanthou, Leonidas Georgiou, Antonis Christofi, Yiannis Roussakis, Cleanthis Ioannides, Kyriakos Spanoudes, Jufeng Zhao, Liyang Yu, Christakis Damianou

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Anastasia AntoniouDepartment of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
Antreas ChrysanthouDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Leonidas GeorgiouDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Antonis ChristofiDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Yiannis RoussakisDepartment of Radiation Oncology, German Medical Institute, Limassol, Cyprus.
Cleanthis IoannidesDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Kyriakos SpanoudesDepartment of Veterinary Medicine, University of Nicosia School of Veterinary Medicine, Nicosia, Cyprus.
Jufeng ZhaoDepartment of Electronics and Information Engineering, Hangzhou Dianzi University, Hangzhou, Zhejiang, China.
Liyang YuDepartment of Electronics and Information Engineering, Hangzhou Dianzi University, Hangzhou, Zhejiang, China.
Christakis DamianouDepartment of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study presents the outcomes of a series of magnetic resonance imaging (MRI)-guided focused ultrasound (MRgFUS) sonications performed on an anatomically accurate head phantom with an embedded tumor simulator to evaluate the effectiveness of partial and complete tumor ablation with obstruction from thin polymer skull mimics. Materials and Methods: The tumor simulator was subjected to single and grid sonications using a single-element concave transducer integrated with an MRI-compatible focused ultrasound (FUS) robotic system. All experiments were carried out in a high-field MRI scanner utilizing proton resonance frequency thermometry and T2-weighted (T2-W) turbo spin echo (TSE) imaging to evaluate the induced thermal effects. FUS transmission through 1-mm thick three-dimensional-printed polymer skull mimics was compared to unobstructed sonication through a circular aperture in the skull model. Results: T2-W TSE imaging demonstrated sharp contrast between the tumor and hyperintense FUS lesions. Complete tumor coverage was achieved through robotic-assisted grid ablation without a skull mimic, as well as with a 1-mm resin skull mimic intervening in the beam. With the lowest attenuation among tested polymers, the resin skull resulted in approximately a 20% reduction in focal temperature change compared to unobstructed sonication, yet still facilitated sharp beam focusing, raising the tumor temperature to ablative levels. Conclusions: The study provides preliminary evidence for the potential application of a thin biocompatible implant to temporarily replace a skull portion facilitating MRgFUS ablation of inoperable tumors using a single-element transducer. The tumor-embedded head phantom was proven effective for testing MRgFUS oncological protocols and equipment.

Indexed as

Focused ultrasoundhead phantommagnetic resonance thermometryrobotic systemT2-weighted turbo spin echo imagingtumor simulator

Identifiers

PMID40256186
PMCPMC12005658

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.