Evidence map›Paper›PMID 40255609›Full record

ArticleVeterinary medicine international2025

A Novel Dynamic Compression Angle-Stable Interlocking Intramedullary Nail: Description, Validation, and Model Evaluation.

Luís Gustavo Gosuen Gonçalves Dias, Thiago André Salvitti Sá Rocha, Caio Afonso Santos Malta, Bruno Watanabe Minto, Alefe Luiz Caliani Carrera

Abstract read
In one paragraph

Article in Veterinary medicine international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Luís Gustavo Gosuen Gonçalves DiasDepartment of Veterinary Clinics and Surgery, School of Agricultural and Veterinarian Sciences of the São Paulo State University (FCAV UNESP), Jaboticabal, State of São Paulo, Brazil.ORCID https://orcid.org/0000-0003-3993-1649
Thiago André Salvitti Sá RochaDepartment of Veterinary Medicine, Federal University of Jatai (UFJ), Jataí, State of Goiás, Brazil.ORCID https://orcid.org/0000-0003-1414-3101
Caio Afonso Santos MaltaDepartment of Veterinary Clinics and Surgery, School of Agricultural and Veterinarian Sciences of the São Paulo State University (FCAV UNESP), Jaboticabal, State of São Paulo, Brazil.ORCID https://orcid.org/0000-0003-4910-6861
Bruno Watanabe MintoDepartment of Veterinary Clinics and Surgery, School of Agricultural and Veterinarian Sciences of the São Paulo State University (FCAV UNESP), Jaboticabal, State of São Paulo, Brazil.ORCID https://orcid.org/0000-0002-8808-4127
Alefe Luiz Caliani CarreraDepartment of Veterinary Clinics and Surgery, School of Agricultural and Veterinarian Sciences of the São Paulo State University (FCAV UNESP), Jaboticabal, State of São Paulo, Brazil.ORCID https://orcid.org/0000-0003-3558-2664

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The stabilization of long-bone fractures using intramedullary nails offers significant biological advantages for bone healing. Nevertheless, the mechanical stability of the implant-bone interface remains suboptimal due to the absence of models capable of generating interfragmentary compression at the fracture site. To address these limitations, this study aims to describe and evaluate a novel dynamic compression angle-stable interlocking intramedullary nail (DCASIN), designed for use in conjunction with a compression device (CD). Its performance was compared with conventional and angle-stable interlocking intramedullary nails. Implantation was demonstrated using a tube-based bone model with transverse fractures. Compression was achieved in the proximal aspect of the DCASIN through an oblong hole that allowed the insertion of a Steinmann pin, which was then subjected to the thrust of the CD's primary screw (PS). To evaluate dynamic compression, a load cell connected to the Arduino/Genuíno Uno software was utilized. Three groups of interlocking nails were assessed: G1 (conventional), G2 (angle-stable), and G3 (DCASIN), with measurements taken at four time points (M1: prelocking, M2: after the first screw or PS for the DCASIN, M3: after the second implant, and M4: one-minute post-M3). No statistically significant differences in compression forces were observed for G1 and G2 across the measured time points. In contrast, G3 exhibited significantly higher compression at M2 than at M3 and M4, and its compression forces at M2, M3, and M4 were significantly greater than those in G1 and G2. Finite element analysis revealed no significant deformation in G3 during compression. In conclusion, the DCASIN combined with the CD achieved and sustained superior compression forces compared to conventional and angle-stable nails, thereby offering a promising alternative for the internal fixation of long bones.

Indexed as

biological osteosynthesisexperimental implantsimplants engineerintramedullary fracture fixationlong bone fractures

Identifiers

PMID40255609
PMCPMC12006711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.