Evidence map›Paper›PMID 40255533›Full record

ArticleStructural dynamics (Melville, N.Y.)2025

Defects in magnetic domain walls after single-shot all-optical switching.

Daniel Metternich, Kai Litzius, Sebastian Wintz, Kathinka Gerlinger, Sascha Petz, Dieter Engel, Themistoklis Sidiropoulos, Riccardo Battistelli, Felix Steinbach, Markus Weigand and 3 more

Abstract read
In one paragraph

Article in Structural dynamics (Melville, N.Y.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Kai LitziusExperimental Physics V, Center for Electronic Correlations and Magnetism, University of Augsburg, 86159 Augsburg, Germany.ORCID https://orcid.org/0000-0002-6408-2581
Sebastian WintzHelmholtz-Zentrum Berlin, 14109 Berlin, Germany.ORCID https://orcid.org/0000-0001-6138-8078
Kathinka GerlingerMax Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0002-4612-3431
Sascha Petz
Dieter EngelMax Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0001-9255-9554
Themistoklis SidiropoulosMax Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0003-3305-3750
Felix SteinbachMax Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0001-9287-1062
Markus WeigandHelmholtz-Zentrum Berlin, 14109 Berlin, Germany.ORCID https://orcid.org/0000-0002-0325-2268
Steffen WittrockHelmholtz-Zentrum Berlin, 14109 Berlin, Germany.ORCID https://orcid.org/0000-0002-9211-6777
Clemens von Korff SchmisingMax Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0003-3159-3489

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Helicity-independent all-optical switching (HI-AOS) is the fastest known way to switch the magnetic order parameter. While the switching process of extended areas is well understood, the formation of domain walls enclosing switched areas remains less explored. Here, we study domain walls around all-optically nucleated magnetic domains using x-ray vector spin imaging and observe a high density of vertical Bloch line defects. Surprisingly, the defect density appears to be independent of optical pulse parameters, significantly varies between materials, and is only slightly higher than in domain walls generated by field cycling. A possible explanation is given by time-resolved Kerr microscopy, which reveals that magnetic domains considerably expand after the initial AOS process. During this expansion, and likewise during field cycling, domain walls propagate at speeds above the Walker breakdown. Micromagnetic simulations suggest that at such speeds, domain walls accumulate defects when moving over magnetic pinning sites, explaining similar defect densities after two very different switching processes. The slightly larger defect density after AOS compared to field-induced switching indicates that some defects are created already when the domain wall comes into existence. Our work shows that engineered low-pinning materials are a key ingredient to uncover the intrinsic dynamics of domain wall formation during ultrafast all-optical switching.

Identifiers

PMID40255533
PMCPMC12009145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.