Evidence map›Paper›PMID 40254534›Full record

ReviewJournal of neurogastroenterology and motility2025

When Manometry and Functional Lumen Imaging Probe Disagree: The Current Limitations of the Chicago Classification Version 4.0 and Probable Extended Indications of Functional Lumen Imaging Probe.

Kee Wook Jung, John E Pandolfino

Abstract readReview
In one paragraph

Review in Journal of neurogastroenterology and motility, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. [Recent Advances in Esophageal Function Testing for Functional Esophageal Disorders].The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Kee Wook JungDepartment of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-3771-3691
John E PandolfinoKenneth C. Griffin Esophageal Center of Northwestern Medicine, Division of Gastroenterology and Hepatology, Department of Medicine, and Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.ORCID https://orcid.org/0000-0002-4993-9559

Funding

NCIRD CDC HHS U01 IP000017
6 · The paper itself

Abstract

High-resolution manometry (HRM) has revolutionized evaluation of esophageal motility disorders, offering detailed pressure topography and refined diagnostic criteria codified through the Chicago classification (CC). However, patients with dysphagia may present with borderline or near-normal HRM findings, exhibiting clinically significant symptoms. CC version 4.0 (v4.0) addresses such scenarios by recommending provocative maneuvers and ancillary tests, notably functional lumen imaging probe (FLIP) and timed barium esophagography. However, growing evidence indicates that FLIP, which measures luminal distensibility under balloon distention, can detect structural or biomechanical abnormalities, such as hypertrophy or fibrosis, that remain inconspicuous on HRM. These discordant findings point to limitations in CC v4.0. FLIP complements HRM by assessing passive tissue properties and capturing balloon-induced contractility, thereby unmasking subtle esophageal wall stiffness not always reflected in integrated relaxation pressure or standard peristaltic metrics. Such discrepancies can arise in early or atypical achalasia, esophagogastric junction outflow obstruction, eosinophilic esophagitis, and even epiphrenic diverticula, where "normal" manometry may belie significant pathology. Present CC v4.0 guidelines do not specify how to incorporate FLIP-derived measures or reconcile disagreements with timed barium esophagography results, leaving certain phenotypes-including repetitive simultaneous contractions-under-recognized. These gaps underscore an overreliance on integrated relaxation pressure alone and insufficient integration of evolving FLIP technology. Thus, standardizing FLIP protocols, establishing normative distensibility data, and clarifying management pathways for manometry-FLIP discordance remain critical. Prospective, multicenter studies are needed to investigate long-term clinical outcomes and to refine how FLIP metrics can be formally integrated into future CC iterations. Ultimately, multimodal, symptom-driven approaches that leverage both HRM and FLIP are essential to fully characterize esophageal dysmotility and optimize therapy.

Indexed as

Deglutition disordersFunctional lumen imaging probeManometry

Identifiers

PMID40254534
PMCPMC12241913

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.