Evidence map›Paper›PMID 40251914›Full record

ArticleJournal of the peripheral nervous system : JPNS2025

New Approaches Based on Serial-Block Face Electron Microscopy to Investigate the Peripheral Nervous System.

Vitalijs Borisovs, Mario Bossi, Laura Matino, Paola Marmiroli, Guido Cavaletti

Abstract read
In one paragraph

Article in Journal of the peripheral nervous system : JPNS, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Vitalijs BorisovsExperimental Neurology Unit, School of Medicine and Surgery, Università di Milano-Bicocca, Monza, Italy.
Mario BossiExperimental Neurology Unit, School of Medicine and Surgery, Università di Milano-Bicocca, Monza, Italy.
Laura MatinoIstituto Degli Endotipi in Oncologia, Metabolismo e Immunologia "Gaetano Salvatore" (IEOMI), Consiglio Nazionale Delle Ricerche, Naples, Italy.
Paola MarmiroliExperimental Neurology Unit, School of Medicine and Surgery, Università di Milano-Bicocca, Monza, Italy.
Guido CavalettiExperimental Neurology Unit, School of Medicine and Surgery, Università di Milano-Bicocca, Monza, Italy.ORCID https://orcid.org/0000-0003-4128-2406

Funding

Ministry of University and Research 2022-202299C3LMinistry of University and Research 2022ZL4JP8
6 · The paper itself

Abstract

BACKGROUND AND

aimsSerial block face scanning electron microscopy (SBF-SEM) enables automated 3D imaging of specimens with ultrastructural resolution. However, its application is often restricted due to the complex and labor-intensive nature of the processes involved. This study addresses the challenges associated with sample preparation and the final 3D reconstruction for ultrastructural analysis of peripheral nerves and dorsal root ganglia (DRG) specimens.

methodsSpecimens from the caudal nerve and DRG of mice were prepared for SBF-SEM using three different techniques: (1) manual high molecular weight staining, regarded as the gold standard, (2) automated standard transmission electron microscopy (TEM) preparation, and (3) automated uranyl-free en bloc preparation. The acquired data were processed by combining different software programs for image analysis and 3D rendering.

resultsUpon analyzing all samples, the high molecular weight method demonstrated its superiority. Nonetheless, the two alternative methods produced high-quality images of the caudal nerve. Consequently, 3D rendering was successfully achieved for all samples using an automated approach. The investigation of DRG specimens posed greater challenges with the standard TEM preparation due to the low contrast of smaller organelles compared to the cytosol, whereas the uranyl-free protocol provided significantly improved contrast.

interpretationOur findings indicate that automated uranyl-free staining can effectively compete with the traditional gold standard manual and uranyl-based staining methods, albeit with some limitations. Furthermore, high-quality SBF-SEM imaging is attainable, especially in peripheral nerves, using samples prepared via the standard TEM method, thereby facilitating the analysis of previously embedded samples even if they were not specifically prepared for 3D examination.

Indexed as

Ganglia, SpinalImaging, Three-DimensionalMicroscopy, Electron, ScanningPeripheral Nervous SystemAnimalsMicedorsal root gangliaperipheral nervescanning electron microscopyserial block face

Identifiers

PMID40251914
PMCPMC12008736

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.