Evidence map›Paper›PMID 40250832›Full record

ArticleJournal of the American Society for Mass Spectrometry2025

Improving MALDI Mass Spectrometry Imaging Performance: Low-Temperature Thermal Evaporation for Controlled Matrix Deposition and Improved Image Quality.

Toufik Mahamdi, Cristina Gomez Serna, Roger Giné, Jordi Rofes, Shad Arif Mohammed, Pere Ràfols, Xavier Correig, María García-Altares, Carsten Hopf, Stefania-Alexandra Iakab and 1 more

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Toufik MahamdiDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.
Cristina Gomez SernaDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.
Roger GinéDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.
Jordi RofesDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.
Shad Arif MohammedCenter for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Str. 10, 68163 Mannheim, Germany.
Pere RàfolsDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.ORCID 0000-0002-9240-4058
Xavier CorreigDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.
María García-AltaresDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.ORCID 0000-0003-4255-1487
Carsten HopfCenter for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Str. 10, 68163 Mannheim, Germany.ORCID 0000-0003-0802-6451
Stefania-Alexandra IakabCenter for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Str. 10, 68163 Mannheim, Germany.ORCID 0000-0002-4156-1942
Oscar YanesDepartment of Electronic Engineering, Universitat Rovira i Virgili, IISPV, 43007 Tarragona, Spain.ORCID 0000-0003-3695-7157

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The deposition of matrix compounds significantly influences the effectiveness of matrix-assisted laser desorption/ionization (MALDI) Mass Spectrometry Imaging (MSI) experiments, impacting sensitivity, spatial resolution, and reproducibility. Dry deposition methods offer advantages by producing homogeneous matrix layers and minimizing analyte delocalization without the use of solvents. However, refining these techniques to precisely control matrix thickness, minimize heating temperatures, and ensure high-purity matrix layers is crucial for optimizing MALDI-MSI performance. Here, we present a novel approach utilizing low-temperature thermal evaporation (LTE) for organic matrix deposition under reduced vacuum pressure. Our method allows for reproducible control of matrix layer thickness, as demonstrated by linear calibration for two organic matrices, 2,5-dihydroxybenzoic acid (DHB) and 1,5-diaminonaphthalene (DAN). The environmental scanning electron microscopy images reveal a uniform distribution of small-sized matrix crystals, consistently on the sub-micrometer scale, across tissue slides following LTE deposition. Remarkably, LTE serves as an additional purification step for organic matrices, producing very pure layers irrespective of initial matrix purity. Furthermore, stability assessment of MALDI-MSI data from mouse brain sections coated with LTE-deposited DHB or DAN matrix indicates minimal impact on ionization efficiency, signal intensity, and image quality even after storage at -80 °C for 2 weeks, underscoring the robustness of LTE-deposited matrices for MSI applications. Comparative analysis with the spray-coating method highlights several advantages of LTE deposition, including enhanced ionization, reduced analyte diffusion, and improved MSI image quality.

Indexed as

Dry DepositionLow Temperature Thermal EvaporationMALDIMass Spectrometry Imaging

Identifiers

PMID40250832
PMCPMC12063169

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.