Evidence map›Paper›PMID 40248939›Full record

ArticleCurrent medical imaging2025

Head and Neck Imaging with a Dental CBCT Device: Comparison of 360° and 180° Rotation Angles in Effective Dose and Quantitative Image Quality in a Phantom Study

Hakan Amasya, Osman Günay, Fatih Kesmezacar, Duygu Tunçman, Nami Yeyin, Eylem Kekeç, Tülin Zengin, Kaan Orhan, Songül Çavdar Karaçam, Mustafa Demir

Abstract readComparative Study
In one paragraph

Article in Current medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hakan AmasyaDepartment of Oral and Dentomaxillofacial Radiology, Faculty of Dentistry, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0001-7400-9938
Osman GünayDepartment of Biomedical Engineering, Faculty of Electrical and Electronics Engineering, Yıldız Technical University, Istanbul, Türkiye.ORCID 0000-0003-0760-554X
Fatih KesmezacarMedical Imag. Tech. Program, Vocational School of Health Services, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0001-5110-1184
Duygu TunçmanRadiotherapy Program, Vocational School of Health Services, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0002-0929-0441
Nami YeyinDepartment of Nuclear Medicine, Cerrahpaşa Faculty of Medicine, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0003-0262-4020
Eylem KekeçNuclear Energy Research Institute, Secondary Standard Dosimetry Laboratory, Istanbul, Türkiye.ORCID 0009-0007-7477-4665
Tülin ZenginNuclear Energy Research Institute, Secondary Standard Dosimetry Laboratory, Istanbul, Türkiye.ORCID 0009-0002-6781-647X
Kaan OrhanDepartment of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Türkiye.ORCID 0000-0001-6768-0176
Songül Çavdar KaraçamRadiotherapy Program, Vocational School of Health Services, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0002-0904-489X
Mustafa DemirDepartment of Nuclear Medicine, Cerrahpaşa Faculty of Medicine, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.ORCID 0000-0002-9813-1628

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study aims to investigate the effect of full- and half-rotation angles on patient radiation dose and quantitative image quality in CBCT imaging of the head and neck region.

methodsA total of 67 TLDs were used for the dosimetry of 16 different regions in the head and neck slices of the anthropometric phantom. The Hyperion X9 Pro (MyRay, Cefla, Imola, Italy) CBCT device was used with a 90 kV pulsed beam and a 13x16e FOV size. Two separate imaging modes (Regular 360 0 and Quick 180 0) were tested, and the mA was determined by the software. Effective doses (EDs) were calculated using the coefficients recommended by ICRP 103 (2007). For the quantitative image quality tests, three VOIs were manually selected for three separate densities in image slices selected from the mandible, maxilla, and paranasal sinus regions of both volumes separately. Pixel values were averaged, and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and uniformity tests were conducted.

resultsIn 360 0, ED was calculated as 1.903 mSv and the highest absorbed dose was found in the oral mucosa (1.566 mSv). In 180 0, ED was calculated as 1.123 mSv and the highest absorbed dose was found in the right temporal squamous region (0.984 mSv). The reduction in ED was found to be 41% for full- and half-rotation angles. Quick/Regular ratios for SNR and CNR were changed between 0.83-0.91.

conclusionThe magnitude of reduction in ED was found to be higher than the quantitative image quality; however, the impact of this change on diagnosis should be analyzed according to the imaging purpose.

Indexed as

Cone-Beam Computed TomographyHeadNeckRadiation DosageHumansPhantoms, ImagingSignal-To-Noise RatioCone-Beam computed tomographyContrast-to-noise ratioDentalRadiationRadiographySignal-to-noise ratio

Identifiers

PMID40248939
PMCPMC13176749

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.