ArticleAJNR. American journal of neuroradiology2025
Remote Robotic Neurointervention: Overcoming Procedural and Connectivity Challenges.
Article in AJNR. American journal of neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- First-in-human use of SmartGUIDENeuroradiology · 2026Article
- Robot-Assisted Mechanical Thrombectomy for Neurointerventional Surgery: An Exploratory Scoping Review.Journal of robotic surgery · 2026Article
- Robotics in Cerebrovascular Disease: The Final Frontier.Missouri medicineReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeAccess to endovascular interventions for neurointerventional procedures remains concentrated in metropolitan centers, limiting availability in smaller cities, rural regions, and developing nations. The feasibility of remote robotic intervention faces several challenges, including enabling full robotic navigation, managing contrast injection, and maintaining stable network connectivity. This study addresses these key obstacles. MATERIALS AND
methodsA robotic system was deployed at the Translational Research Imaging Center Lab at University of California, Los Angeles. Connectivity was assessed both before and during the procedures. Five remote neurointerventionalists operated 4 devices: 2 novel steerable catheters, 1 off-the-shelf microcatheter, and 1 guidewire from femoral access to the MCA in a silicone vascular model. Radiopaque contrast injections were performed, and audiovisual communication was maintained throughout. Connectivity metrics, including round-trip time (RTT) and bandwidth, were monitored. Primary end points included successful navigation to the MCA within 15 minutes, first-attempt vessel entry rate, and episodes of tooltip contact with the vessel wall.
resultsFollowing catheter placement in the femoral sheath, all procedures were fully robotically controlled without bedside intervention. Procedural times ranged from 11 minutes 1 second to 14 minutes, with a mean RTT of <150 ms; 2 brief episodes of unsafe latency (RTT of >150 ms) were recorded. First-attempt vessel entry was successful in 84.2% of cases, and minimal vessel wall contact occurred (1-2 episodes per procedure).
conclusionsThis study demonstrates the feasibility of remote robotic neurointervention, effectively addressing key challenges in robot-assisted endovascular procedures and network connectivity management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials