Impact of three-dimensional stabilization thread design on biomechanical fixation and osseointegration of endosteal implants.

Blaire V Slavin, Vasudev Vivekanand Nayak, Edmara T P Bergamo, Joseph P Costello, Quinn T Ehlen, Zachary M Stauber, Natalia Fullerton, Lukasz Witek, Paulo G Coelho

Abstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Blaire V SlavinUniversity of Miami Miller School of Medicine, Miami, FL, USA.
Vasudev Vivekanand NayakDepartment of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, USA; Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute (BioNIUM), University of Miami, Miami, FL, USA.
Edmara T P BergamoDepartment of Prosthodontics, NYU College of Dentistry, New York, NY, USA; Biomaterials and Regenerative Biology Division, NYU College of Dentistry, New York, NY, USA.
Joseph P CostelloUniversity of Miami Miller School of Medicine, Miami, FL, USA.
Quinn T EhlenUniversity of Miami Miller School of Medicine, Miami, FL, USA.
Zachary M StauberUniversity of Miami Miller School of Medicine, Miami, FL, USA.
Natalia FullertonDeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, University of Miami Miller School of Medicine, Miami, FL, USA.
Lukasz WitekBiomaterials and Regenerative Biology Division, NYU College of Dentistry, New York, NY, USA; Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, NY, USA; Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY, USA; Department of Oral and Maxillofacial Surgery, NYU College of Dentistry, New York, NY, USA. Electronic address: lukasz.witek@nyu.edu.
Paulo G CoelhoDepartment of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, USA; Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute (BioNIUM), University of Miami, Miami, FL, USA; DeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, University of Miami Miller School of Medicine, Miami, FL, USA.

Funding

Field Emission Scanning Electron MicroscopeS10OD026989 · OD · NEW YORK UNIVERSITY · PI BROMAGE, TIMOTHY G. · 2019 to 2019
$581k
NIH HHS S10 OD026989
6 · The paper itself

Abstract

backgroundImplant's primary stability is determined by the intimate and immediate contact between the implant and osteotomy wall, whereas secondary stability is primarily influenced by healing chambers that facilitate the bone formation and remodeling processes following placement. Therefore, modifications to macro-geometric parameters are essential to elicit the desired in vivo response and to ensure successful osseointegration. Three-dimensional (3D) stabilization thread forms comprise both curved and linear geometric surfaces across the thread's crest maximizing retention forces while constraining lateral movement under load relative to conventional buttress-threaded implants.

methodsThis study utilized Ti-6Al-4V ELI implants with (i) a buttress thread design [Tapered Pro, BioHorizons®, Birmingham, AL, USA] (TP - control) compared to (ii) a novel, patented, 3D stabilization trimmed-thread design (TP 3DS - experimental). Implants were placed in the mandible of sheep (N = 14 sheep, 6 implants per group per sheep) and allowed to heal for 3- and 12-weeks (N = 7 sheep per time point). During implant placement (T = 0 weeks), the maximum insertion torque value (ITV) and implant stability quotient (ISQ) were measured by torque-in testing and resonance frequency analysis, respectively. After the healing periods, subjects were euthanized, and samples harvested en bloc for biomechanical evaluation via lateral loading tests in addition to histomorphometric and nanoindentation analysis.

resultsITV values were significantly lower in the TP 3DS group compared to TP (p < 0.001). Both groups presented ISQ values ≥ 70, indicating high primary stability. Relative to the TP group, TP 3DS exhibited a significant (∼1.85-fold) increase in lateral load at 3 weeks (p = 0.029) and comparable load values at 12 weeks (p > 0.05). No quantitative differences in percentage of bone-to-implant contact (BIC) and bone-area-fraction-occupancy (BAFO) were observed at either time points between the two thread designs (p > 0.05). Similarly, no differences in bone's mechanical properties (Young's modulus (E) and Hardness (H)) between TP and TP 3DS were observed at 3- and 12- weeks (p > 0.05). Qualitatively, scattered microcracks were apparent at the outer threads of the implant, particularly within the TP group, whereas small bone chips were interspersed between threads of the 3DS implant serving as additional nucleation sites for bone formation.

conclusionThe TP 3DS design reduced insertion torque, improved lateral loading competence, and resulted in a healing pattern, that are beneficial during early stages of osseointegration compared to TP implants.

Indexed as

Dental ImplantsMechanical PhenomenaOsseointegrationAlloysAnimalsBiomechanical PhenomenaMandibleMaterials TestingSheepTitaniumAlloysDental ImplantsTitaniumtitanium alloy (TiAl6V4)Dental implantsInsertion torqueOsseointegrationPrimary stabilityResonance frequency analysis

Identifiers

PMID40245678
PMCPMC12344789

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.