Evidence map›Paper›PMID 40245269›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2025

Tailored 3D Lattice Microstructures for Enhanced Functionality in Blood-Gas Exchange.

Kai P Barbian, Teresa Lemainque, Ina Grunden, Roman Iwa, Bettina Wiegmann, John Linkhorst, Matthias Wessling, Jan Heyer, Ulrich Steinseifer, Michael Neidlin and 1 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. 3D Membrane Microstructures for Increased Efficiency in Blood-Gas Transfer.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  3. Tailored 3D Lattice Microstructures for Enhanced Functionality in Blood-Gas Exchange.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kai P BarbianDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.ORCID https://orcid.org/0009-0009-2749-3777
Teresa LemainqueDepartment of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, 52074, Aachen, Germany.
Ina GrundenDepartment of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, 52074, Aachen, Germany.
Roman IwaDepartment of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, 52074, Aachen, Germany.
Bettina WiegmannDepartment for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
John LinkhorstChemical Process Engineering (AVT.CVT), RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany.
Matthias WesslingChemical Process Engineering (AVT.CVT), RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany.
Jan HeyerDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.
Ulrich SteinseiferDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.
Michael NeidlinDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.
Sebastian V JansenDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.

Funding

German Research Foundation (DFG) 347368182
6 · The paper itself

Abstract

Current membrane oxygenators for extracorporeal life support (ECLS) are facing their limits regarding gas exchange efficiency and long-term stability. One aspect adding to these limitations is inhomogeneous blood flow distribution inside the oxygenator's membrane structure. Triply periodic minimal surface (TPMS) lattice structures are proposed to provide increased mass transfer efficiency and local adaptability introducing heterogeneous properties. However, the adaptation of these structures for blood flow, as in ECLS, is challenging as a hemocompatible flow distribution must be established. In this study, this study proposes a novel method for the smooth, multi-scale modification of TPMS lattice structures creating a tailored flow distribution suited for blood-gas exchange. It implements this method into an automatic structure optimization within an oxygenator. After manufacturing prototypes, it experimentally evaluate the 3D flow distribution using time-resolved, contrast enhanced computed tomography comparing the optimized structure to reference geometries. The TPMS structure modification provides a significant change in flow distribution, improving homogeneity by up to 12%. The approach to creating tailored 3D TPMS lattice structures can be directly transferred to various other applications in the field of heat and mass transfer to enhance functionality, e.g., for heat exchangers or membrane contactors.

Indexed as

Extracorporeal Membrane OxygenationOxygenators, MembraneEquipment DesignHumansadditive manufacturingdesign optimizationflow homogeneitylattice structuresmembrane oxygenatorsstructure adaptationtpms

Identifiers

PMID40245269
PMCPMC12224992

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.