Evidence map›Paper›PMID 40244551›Full record

ArticleAnnals of biomedical engineering2025

Heparin Coating Decreases the Thrombotic Signature of Flow Diverter Stents.

Sina Farzaneh, Juan Miguel Jiménez

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sina FarzanehDepartment of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA, USA.
Juan Miguel JiménezDepartment of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA, USA. juanjimenez@umass.edu.ORCID http://orcid.org/0000-0002-3915-2883

Funding

Scanning Electron Microscope for Core EM FacilityS10RR021043 · NCRR · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI CRAIG, ROGER W · 2007 to 2007
$498k
NCRR NIH HHS S10RR021043
6 · The paper itself

Abstract

purposeFlow diverter stents (FDS) are used to treat aneurysms by modifying the intraaneurysmal hemodynamics and promoting a prothrombotic milieu. Thrombotic in-stent stenosis (ISS) is a common complication of endovascular treatment for intracranial aneurysms with flow diverter stents. The dominant approach to address ISS has been to either increase the dose of antiplatelet therapy agents or extend dual antiplatelet therapy (DAPT) causing ISS to resolve, while potentially exacerbating the side effects associated with DAPT. To decrease the risk of thrombotic ISS, surface coatings have been applied to flow diverter stents with promising results.

methodsThe thrombotic signature of a bare metal and a heparin coated FDS was assessed in vitro. The flow diverter stents were exposed to pulsatile blood flow in a one-pass system to assess platelet and fibrin deposition, while flow cytometry was used to assess different markers of platelet activation in blood incubated with flow diverter stents for 30, 60, and 90 minutes.

resultsImmunofluorescence and scanning electron microcopy results demonstrated greater fibrin and platelet deposition on bare metal flow diverter stents, while the heparin coated flow diverter stents had less fibrin and platelet deposition. A greater percentage of platelets were not only activated, but also presented higher levels of activation markers, in blood exposed to the bare metal flow diverter stents at the 90 minute time point in comparison to the heparin coated FDS.

conclusionThe findings demonstrate that heparin coated flow diverter stents are characterized by a lower thrombotic signature than bare metal flow diverter stents and raise the possibility of an additional therapeutic option to treat intracranial aneurysms.

Indexed as

Coated Materials, BiocompatibleDrug-Eluting StentsHeparinStentsThrombosisBlood PlateletsHumansIntracranial AneurysmPlatelet ActivationCoated Materials, BiocompatibleHeparinAnti-thrombotic coatingFlow diverter stentHeparinIn-stent stenosisIntracranial aneurysms

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.