Evidence map›Paper›PMID 40244313›Full record

ArticleJournal of medical ultrasonics (2001)2025

Automated scheme of plaque classification based on segmentation in carotid ultrasound images using transformer approach.

Gakuto Hirano, Atsushi Teramoto, Hiroji Takai, Yutaka Sasaki, Keiko Sugimoto, Shoji Matsumoto, Kuniaki Saito, Hiroshi Fujita

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gakuto HiranoGraduate School of Health Sciences, Fujita Health University, Toyoake, Japan.
Atsushi TeramotoFaculty of Information Engineering, Meijo University, 1-501 Shiogamaguchi, Tempaku-ku, Nagoya, 468-8502, Japan. teramoto@meijo-u.ac.jp.
Hiroji TakaiDepartment of Radiology, Fujita Health University Hospital, Toyoake, Japan.
Yutaka SasakiDepartment of Clinical Laboratory, Fujita Health University Hospital, Toyoake, Japan.
Keiko SugimotoGraduate School of Health Sciences, Fujita Health University, Toyoake, Japan.
Shoji MatsumotoDepartment of Comprehensive Strokology, School of Medicine, Fujita Health University, Toyoake, Japan.
Kuniaki SaitoGraduate School of Health Sciences, Fujita Health University, Toyoake, Japan.
Hiroshi FujitaFaculty of Engineering, Gifu University, Gifu, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCarotid plaque is a major risk factor for cerebral infarction. Ultrasonography (US) is extensively used for screening carotid plaque, but US images contain more noise than those of computed tomography and magnetic resonance imaging, and the edges of the plaque regions are unclear. In addition, B-mode echogenicity evaluation, which is important for plaque risk assessment, has challenges involving the subjectivity of the evaluator. Although previous studies on carotid plaque assessment have included plaque segmentation, most studies involved manual operations. In this study, we propose an automated scheme of plaque classification based on segmentation in carotid US images using the transformer approach, to resolve the issues of previous studies and to perform plaque echogenicity classification.

methodsThe B-mode video captured in the long-axis cross-section was converted to still images, and region extraction and echogenicity classification were performed using TransUNet. The results of the TransUNet output and US images were fed into the Vision Transformer (ViT) for classification into hypoechoic or isoechoic-hyperechoic plaques.

resultsThe Dice index, which indicates the accuracy of plaque region extraction, was 0.592. The Dice indices by echogenicity were 0.200, 0.493, and 0.542 for the hypoechoic, isoechoic, and hyperechoic regions, respectively. The balanced accuracy, which indicates the classification accuracy, was 79.6%. The correct classification rate for high-risk hypoechoic plaques was 95.2%.

conclusionThese results suggest that the proposed method is useful for evaluating the echogenicity classification of carotid artery plaques.

Indexed as

Carotid ArteriesCarotid Artery DiseasesCarotid StenosisImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedPlaque, AtheroscleroticHumansMaleUltrasonographyUltrasonography, Carotid ArteriesCarotid plaqueClassificationDeep learningSegmentationTransformerUltrasound

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.